diff --git a/software/osie-coupler/instance-input-schema.json b/software/osie-coupler/instance-input-schema.json index 25d22584c803c176a2d6e6fdcbb626488ac214fe..5cef2cfea9fc6388e71be9b668bad23c29199641 100644 --- a/software/osie-coupler/instance-input-schema.json +++ b/software/osie-coupler/instance-input-schema.json @@ -3,78 +3,65 @@ "description": "Parameters to instantiate coupler", "type": "object", "configuration": { - - "coupler_block_device": { + "coupler_block_device": { "description": "The Linux block device using I2C protocol,", "type": "string", "default": "/dev/i2c-1" }, - - "coupler_i2c_slave_list": { + "coupler_i2c_slave_list": { "description": "The list of comma separated addresses of I2C enabled devices on the I2C bus.", "type": "string", "default": "0x58" }, - - "opc_ua_port": { + "opc_ua_port": { "description": "The OPC UA server bind to bind to.", "type": "integer", "default": 4840 - }, - - "mode": { - "description": "The operationg mode of the coupler. By default 0 - i.e. control for real I2C devices attached. If 1 selected emulate them (useful for testing). ", + }, + "mode": { + "description": "The operation mode of the coupler. By default 0 - i.e. control for real I2C devices attached. If 1 selected emulate them (useful for testing). ", "type": "integer", "default": 0 - }, - - "id": { + }, + "id": { "description": "The numeric ID of the coupler", "type": "integer", "default": 0 - }, - - "username": { + }, + "username": { "description": "The username for OPC UA server.", "type": "string", "default": "" }, - - "password": { + "password": { "description": "The password for OPC UA server.", "type": "string", "default": "" }, - - "heart_beat": { + "heart_beat": { "description": "Indication if coupler should send heart beats over a keep-alive network.", "type": "boolean", "default": 0 }, - - "heart_beat_interval": { + "heart_beat_interval": { "description": "The heart beat interval (in ms)", "type": "integer", "default": 500 }, - - "heart_beat_id_list": { + "heart_beat_id_list": { "description": "A comma separated list of couplers' IDs which should send to us keep-alive messages. ", "type": "string", "default": "" }, - - "heart_beat_timeout_interval": { + "heart_beat_timeout_interval": { "description": "The timeout (in ms) which when expired without a keep alive message will cause the coupler to go to a safe mode. ", "type": "integer", "default": 2000 }, - - "network_address_url_data_type": { + "network_address_url_data_type": { "description": "Network address URL type used for Pub/Sub.", "type": "string", "default": "opc.udp://224.0.0.22:4840/" } - } }