• Heiko Carstens's avatar
    [S390] cio: use INIT_WORK to initialize struct work. · 33583c36
    Heiko Carstens authored
    Use INIT_WORK to initialize struct work and don't initialize a
    struct work partial by explicitly initializing its private structures.
    Fixes the following lockdep bug because no key was assigned:
    
    INFO: trying to register non-static key.
    the code is fine but needs lockdep annotation.
    turning off the locking correctness validator.
    0000000001f07bb8 0000000001f07bf8 0000000000000002 0000000000000000
           0000000001f07c98 0000000001f07c10 0000000001f07c10 0000000000015406
           0000000000000000 0000000000000002 0000000000000000 0000000000000000
           0000000001f07bf8 000000000000000c 0000000001f07bf8 0000000001f07c68
           000000000039ae60 0000000000015406 0000000001f07bf8 0000000001f07c48
    Call Trace:
    ([<0000000000015376>] show_trace+0xda/0x104)
     [<0000000000015460>] show_stack+0xc0/0xf8
     [<00000000000154c6>] dump_stack+0x2e/0x3c
     [<000000000006a71e>] __lock_acquire+0x47e/0x11a0
     [<000000000006b4f0>] lock_acquire+0xb0/0xd8
     [<00000000000555a6>] run_workqueue+0x1aa/0x24c
     [<00000000000556de>] worker_thread+0x96/0xf4
     [<000000000005c210>] kthread+0x90/0xb4
     [<000000000001947a>] kernel_thread_starter+0x6/0xc
     [<0000000000019474>] kernel_thread_starter+0x0/0xc
    Signed-off-by: default avatarHeiko Carstens <heiko.carstens@de.ibm.com>
    Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
    33583c36
device.c 36.9 KB