Vitaly Lifshits authored
On some Meteor Lake systems accessing the PHY via the MDIO interface may result in an MDI error. This issue happens sporadically and in most cases a second access to the PHY via the MDIO interface results in success. As a workaround, introduce a retry counter which is set to 3 on Meteor Lake systems. The driver will only return an error if 3 consecutive PHY access attempts fail. The retry mechanism is disabled in specific flows, where MDI errors are expected. Fixes: cc23f4f0 ("e1000e: Add support for Meteor Lake") Suggested-by: Nikolay Mushayev <nikolay.mushayev@intel.com> Co-developed-by: Nir Efrati <nir.efrati@intel.com> Signed-off-by: Nir Efrati <nir.efrati@intel.com> Signed-off-by: Vitaly Lifshits <vitaly.lifshits@intel.com> Tested-by: Naama Meir <naamax.meir@linux.intel.com> Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>
6dbdd4de