Fabrice Gasnier authored
When doing successive oversampling settings, it may fail to update filter parameters silently: - First time oversampling is being set, it will be successful, as fl->res is 0 initially. - Next attempts with various oversamp value may return 0 (success), but keep previous filter parameters, due to 'res' never reaches above or equal current 'fl->res'. This is particularly true when setting sampling frequency (that relies on oversamp). Typical failure without error: - run 1st test @16kHz samp freq will succeed - run new test @8kHz will succeed as well - run new test @16kHz (again): sample rate will remain 8kHz without error Fixes: e2e6771c ("IIO: ADC: add STM32 DFSDM sigma delta ADC support") Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com> Acked-by: Arnaud Pouliquen <arnaud.pouliquen@st.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>