Zhao Chen authored
This patch fixes the problem below. The problem can be reproduced by the following steps: 1) Connecting all HiNIC interfaces 2) On server side # sudo ifconfig eth0 192.168.100.1 up #Using MLX CX4 card # iperf -s 3) On client side # sudo ifconfig eth0 192.168.100.2 up #Using our HiNIC card # iperf -c 192.168.101.1 -P 10 -t 100000 after hours of testing, we will see errors: hinic 0000:05:00.0: No MGMT msg handler, mod = 0 hinic 0000:05:00.0: No MGMT msg handler, mod = 0 hinic 0000:05:00.0: No MGMT msg handler, mod = 0 hinic 0000:05:00.0: No MGMT msg handler, mod = 0 The errors are caused by the following problem. 1) The hinic_get_wqe() checks the "wq->delta" to allocate new WQEs: if (atomic_sub_return(num_wqebbs, &wq->delta) <= 0) { atomic_add(num_wqebbs, &wq->delta); return ERR_PTR(-EBUSY); } If the WQE occupies multiple pages, the shadow WQE will be used. Then the hinic_xmit_frame() fills the WQE. 2) While in parallel with 1), the free_tx_poll() checks the "wq->delta" to free old WQEs: if ((atomic_read(&wq->delta) + num_wqebbs) > wq->q_depth) return ERR_PTR(-EBUSY); There is a probability that the shadow WQE which hinic_xmit_frame() is using will be damaged by copy_wqe_to_shadow(): if (curr_pg != end_pg) { void *shadow_addr = &wq->shadow_wqe[curr_pg * wq->max_wqe_size]; copy_wqe_to_shadow(wq, shadow_addr, num_wqebbs, *cons_idx); return shadow_addr; } This can cause WQE data error and you will see the above error messages. This patch fixes the problem. Signed-off-by: Zhao Chen <zhaochen6@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
9c2956d2