Philipp Rossak authored
The ADC Command Buffer Register high and low are currently pointing to the wrong address and makes it impossible to perform correct ADC measurements over all channels. According to the datasheet of the imx8qxp the ADC_CMDL register starts at address 0x100 and the ADC_CMDH register starts at address 0x104. This bug seems to be in the kernel since the introduction of this driver. This can be observed by checking all raw voltages of the adc and they are all nearly identical: cat /sys/bus/iio/devices/iio\:device0/in_voltage*_raw 3498 3494 3491 3491 3489 3490 3490 3490 Fixes: 1e23dcaa ("iio: imx8qxp-adc: Add driver support for NXP IMX8QXP ADC") Signed-off-by: Philipp Rossak <embed3d@gmail.com> Acked-by: Haibo Chen <haibo.chen@nxp.com> Link: https://lore.kernel.org/r/20230904220204.23841-1-embed3d@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
850101b3