Commit 92af0fb2 authored by Jonathan Cameron's avatar Jonathan Cameron

dt-bindings:iio:temperature:melexis,mlx90632 conversion to yaml

Technically this could have gone in trivial-devices.yaml, but I have
kept it as a separate binding due to the detailed additional description
from the text file.
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: default avatarRob Herring <robh@kernel.org>
Acked-by: default avatarCrt Mori <cmo@melexis.com>
Cc: Crt Mori <cmo@melexis.com>
Link: https://lore.kernel.org/r/20201031134110.724233-26-jic23@kernel.org
parent 39616b4e
# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Melexis MLX90632 contactless Infra Red temperature sensor
maintainers:
- Crt Mori <cmo@melexis.com>
description: |
https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
There are various applications for the Infra Red contactless temperature
sensor and MLX90632 is most suitable for consumer applications where
measured object temperature is in range between -20 to 200 degrees
Celsius with relative error of measurement below 1 degree Celsius in
object temperature range for industrial applications. Since it can
operate and measure ambient temperature in range of -20 to 85 degrees
Celsius it is suitable also for outdoor use.
Be aware that electronics surrounding the sensor can increase ambient
temperature. MLX90632 can be calibrated to reduce the housing effect via
already existing EEPROM parameters.
Since measured object emissivity effects Infra Red energy emitted,
emissivity should be set before requesting the object temperature.
properties:
compatible:
const: melexis,mlx90632
reg:
maxItems: 1
description: Default is 0x3a, but can be reprogrammed.
required:
- compatible
- reg
additionalProperties: false
examples:
- |
i2c {
#address-cells = <1>;
#size-cells = <0>;
temp-sensor@3a {
compatible = "melexis,mlx90632";
reg = <0x3a>;
};
};
...
* Melexis MLX90632 contactless Infra Red temperature sensor
Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
There are various applications for the Infra Red contactless temperature sensor
and MLX90632 is most suitable for consumer applications where measured object
temperature is in range between -20 to 200 degrees Celsius with relative error
of measurement below 1 degree Celsius in object temperature range for
industrial applications. Since it can operate and measure ambient temperature
in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
Be aware that electronics surrounding the sensor can increase ambient
temperature. MLX90632 can be calibrated to reduce the housing effect via
already existing EEPROM parameters.
Since measured object emissivity effects Infra Red energy emitted, emissivity
should be set before requesting the object temperature.
Required properties:
- compatible: should be "melexis,mlx90632"
- reg: the I2C address of the sensor (default 0x3a)
Example:
mlx90632@3a {
compatible = "melexis,mlx90632";
reg = <0x3a>;
};