iio: xilinx-ams: Add labels
Label all the channels using names from the reference manual. Some of the "control" channels are duplicates of other channels. The reference manual describes it like: > The AMS register set includes several measurement registers that are > written to by the PS SYSMON unit using the single-channel mode > (sequencer off). These voltage measurements are performed using the > unipolar sampling circuit with a 0 to 3V range and do not have alarms > or minimum/maximum registers. So I think these really are measuring the same voltages but in a different location. In which case, sharing labels makes sense to me. Signed-off-by: Sean Anderson <sean.anderson@linux.dev> Link: https://patch.msgid.link/20240620204842.817237-1-sean.anderson@linux.devSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>