Commit b962f5a4 authored by Stewart Smith's avatar Stewart Smith Committed by Michael Ellerman

powerpc/powernv: only register log if OPAL supports doing so

Correct use of REGISTER/UNREGISTER is to check if the token exists
before calling. If we don't we get a "OPAL: Called with bad token 101 !"
error, which is harmless but may be alarming to some.
Signed-off-by: default avatarStewart Smith <stewart@linux.vnet.ibm.com>
Acked-by: default avatarVasant Hegde <hegdevasant@linux.vnet.ibm.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
parent df99e6eb
......@@ -665,6 +665,9 @@ static void __init opal_dump_region_init(void)
uint64_t size;
int rc;
if (!opal_check_token(OPAL_REGISTER_DUMP_REGION))
return;
/* Register kernel log buffer */
addr = log_buf_addr_get();
if (addr == NULL)
......@@ -823,6 +826,7 @@ void opal_shutdown(void)
}
/* Unregister memory dump region */
if (opal_check_token(OPAL_UNREGISTER_DUMP_REGION))
opal_unregister_dump_region(OPAL_DUMP_REGION_LOG_BUF);
}
......