Commit c89e5eb7 authored by Geert Uytterhoeven's avatar Geert Uytterhoeven Committed by Marc Zyngier

dt-bindings: interrupt-controller: sifive,plic: Group interrupt tuples

To improve human readability and enable automatic validation, the tuples
in "interrupts-extended" properties should be grouped using angle
brackets.
Signed-off-by: default avatarGeert Uytterhoeven <geert@linux-m68k.org>
Reviewed-by: default avatarRob Herring <robh@kernel.org>
Reviewed-by: default avatarAnup Patel <anup@brainfault.org>
Signed-off-by: default avatarMarc Zyngier <maz@kernel.org>
Link: https://lore.kernel.org/r/211705e74a2ce77de43d036c5dea032484119bf7.1643360419.git.geert@linux-m68k.org
parent 8fbc16d2
......@@ -90,12 +90,11 @@ examples:
#interrupt-cells = <1>;
compatible = "sifive,fu540-c000-plic", "sifive,plic-1.0.0";
interrupt-controller;
interrupts-extended = <
&cpu0_intc 11
&cpu1_intc 11 &cpu1_intc 9
&cpu2_intc 11 &cpu2_intc 9
&cpu3_intc 11 &cpu3_intc 9
&cpu4_intc 11 &cpu4_intc 9>;
interrupts-extended = <&cpu0_intc 11>,
<&cpu1_intc 11>, <&cpu1_intc 9>,
<&cpu2_intc 11>, <&cpu2_intc 9>,
<&cpu3_intc 11>, <&cpu3_intc 9>,
<&cpu4_intc 11>, <&cpu4_intc 9>;
reg = <0xc000000 0x4000000>;
riscv,ndev = <10>;
};