-
Martin Schwidefsky authored
Git commit 4f37a68c "s390: Use direct ktime path for s390 clockevent device" makes use of the CLOCK_EVT_FEAT_KTIME clockevent option to avoid the delta calculation with ktime_get() in clockevents_program_event and the get_tod_clock() in s390_next_event. This is based on the assumption that the difference between the internal ktime and the hardware clock is reflected in the wall_to_monotonic delta. But this is not true, the ntp corrections are applied via changes to the tk->mult multiplier and this is not reflected in wall_to_monotonic. In theory this could be solved by using the raw monotonic clock but it is simpler to switch back to the standard clock delta calculation. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
8adbf78e