Nicholas Piggin authored
A synchronous machine check is an exception raised by the attempt to execute the current instruction. If the error can't be corrected, it can make sense to SIGBUS the currently running process. In other cases, the error condition is not related to the current instruction, so killing the current process is not the right thing to do. Today, all machine checks are MCE_SEV_ERROR_SYNC, so this has no practical change. It will be used to handle POWER9 asynchronous machine checks. Signed-off-by: Nicholas Piggin <npiggin@gmail.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
1363875b