• Karthikeyan Periyasamy's avatar
    ath10k: fix spectral scan for QCA9984 and QCA9888 chipsets · 2e9bcd0d
    Karthikeyan Periyasamy authored
    The spectral scan has been always broken on QCA9984 and QCA9888.
    
    Introduce a hardware parameter 'spectral_bin_offset' to resolve this issue for
    QCA9984 and QCA9888 chipsets. For other chipsets, the hardware parameter
    'spectral_bin_offset' is zero so that existing behaviour is retained as it is.
    
    In QCA9984 and QCA9888 chipsets, hardware param value 'spectral_bin_discard'
    is 12 bytes. This 12 bytes is derived as the sum of segment index (4 bytes),
    extra bins before the actual data (4 bytes) and extra bins after the actual
    data (4 bytes). Always discarding (12 bytes) happens at end of the samples and
    incorrect samples got dumped, so that user can find incorrect arrangement
    samples in spectral scan dump.
    
    To fix this issue, we have to discard first 8 bytes and last 4 bytes in every
    samples, so totally 12 bytes are discarded. In every sample we need to consider
    the offset while taking the actual spectral data. For QCA9984, QCA9888 the
    offset is 8 bytes (segment index + extra bins before actual data).
    
    Hardware tested: QCA9984 and QCA9888
    Firmware tested: 10.4-3.5.3-00053
    Signed-off-by: default avatarKarthikeyan Periyasamy <periyasa@codeaurora.org>
    Signed-off-by: default avatarKalle Valo <kvalo@codeaurora.org>
    2e9bcd0d