Zhaolei authored
"echo noglobal-clock > trace_options" can be used to change trace clock but "echo 0 > options/global-clock" can't. The flag toggling will be silently accepted without actually changing the clock callback. We can fix it by using set_tracer_flags() in trace_options_core_write(). Changelog: v1->v2: Simplified switch() after Li Zefan <lizf@cn.fujitsu.com>'s suggestion Signed-off-by: Zhao Lei <zhaolei@cn.fujitsu.com> Cc: Steven Rostedt <srostedt@redhat.com> Cc: Li Zefan <lizf@cn.fujitsu.com> Signed-off-by: Frederic Weisbecker <fweisbec@gmail.com>
f2d84b65