Alexandre Belloni authored
From the datasheet, the actual duty cycle is: (period - (1 / clk) * CDTY) / period This actually correct the polarity of the PWM and solves the issue that pwm-leds exhibits: when setting a duty cycle of 0 and then disabling a channel, the level was wrong (1 when the polarity was normal and 0 when the polarity was inversed). Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com> Acked-by: Nicolas Ferre <nicolas.ferre@atmel.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>