Commit 0f8b9c77 authored by Sangbeom Kim's avatar Sangbeom Kim Committed by Mark Brown

regulator: Fix s5m8767_set_voltage_time_sel calculation value

In the s5m8767_set_voltage_time_sel function, divisor unit is wrong.
ramp_delay is usec unit. So 1000 should be multiplied.
Signed-off-by: default avatarSangbeom Kim <sbkim73@samsung.com>
Signed-off-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
parent 394ee3d5
...@@ -457,7 +457,7 @@ static int s5m8767_set_voltage_time_sel(struct regulator_dev *rdev, ...@@ -457,7 +457,7 @@ static int s5m8767_set_voltage_time_sel(struct regulator_dev *rdev,
if (old_sel < new_sel) if (old_sel < new_sel)
return DIV_ROUND_UP(desc->step * (new_sel - old_sel), return DIV_ROUND_UP(desc->step * (new_sel - old_sel),
s5m8767->ramp_delay); s5m8767->ramp_delay * 1000);
return 0; return 0;
} }
......