Commit 49a59543 authored by Johannes Berg's avatar Johannes Berg Committed by John W. Linville

mac80211: dont assign seqno to or aggregate QoS Null frames

802.11 says:
"Sequence numbers for QoS (+)Null frames may be
set to any value."

However, if we use the normal counters then peers
will get confused with aggregation since there'll
be holes in the sequence number sequence.

To avoid that, neither assign a sequence number
to QoS null frames nor put them on aggregation.
Signed-off-by: default avatarJohannes Berg <johannes.berg@intel.com>
Signed-off-by: default avatarJohn W. Linville <linville@tuxdriver.com>
parent 4b801bc9
...@@ -804,6 +804,9 @@ ieee80211_tx_h_sequence(struct ieee80211_tx_data *tx) ...@@ -804,6 +804,9 @@ ieee80211_tx_h_sequence(struct ieee80211_tx_data *tx)
if (ieee80211_hdrlen(hdr->frame_control) < 24) if (ieee80211_hdrlen(hdr->frame_control) < 24)
return TX_CONTINUE; return TX_CONTINUE;
if (ieee80211_is_qos_nullfunc(hdr->frame_control))
return TX_CONTINUE;
/* /*
* Anything but QoS data that has a sequence number field * Anything but QoS data that has a sequence number field
* (is long enough) gets a sequence number from the global * (is long enough) gets a sequence number from the global
...@@ -1236,6 +1239,7 @@ ieee80211_tx_prepare(struct ieee80211_sub_if_data *sdata, ...@@ -1236,6 +1239,7 @@ ieee80211_tx_prepare(struct ieee80211_sub_if_data *sdata,
tx->sta = sta_info_get(sdata, hdr->addr1); tx->sta = sta_info_get(sdata, hdr->addr1);
if (tx->sta && ieee80211_is_data_qos(hdr->frame_control) && if (tx->sta && ieee80211_is_data_qos(hdr->frame_control) &&
!ieee80211_is_qos_nullfunc(hdr->frame_control) &&
(local->hw.flags & IEEE80211_HW_AMPDU_AGGREGATION) && (local->hw.flags & IEEE80211_HW_AMPDU_AGGREGATION) &&
!(local->hw.flags & IEEE80211_HW_TX_AMPDU_SETUP_IN_HW)) { !(local->hw.flags & IEEE80211_HW_TX_AMPDU_SETUP_IN_HW)) {
struct tid_ampdu_tx *tid_tx; struct tid_ampdu_tx *tid_tx;
......