Commit 74b52cc4 authored by Claes Sjofors's avatar Claes Sjofors

Doc changes

parent 25a6dc17
......@@ -2462,7 +2462,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
EndObject
Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00
Body RtBody 27-JAN-2014 10:47:40.34
Body RtBody 06-FEB-2014 14:25:41.14
Attr Specification = "ABB ACS800 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5_IoModule.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5_IoModule.I_IND"
......@@ -51770,7 +51770,11 @@ if (I1 >= 0 && I1 <= 9) {
!
! @b Settings 3
! Parameter group 33 to 50 settings to be performed.
! NoteGroup 50 index 2 "comm loss func" is important.
! Note Group 50 index 2 "comm loss func" is important.
! Warning message 'change fan' in the driver need some settings in
! parameter group 33. 'On-time 1 Warn limit 33.11 is set to two
! years run time (63072000 seconds). 'On-time 1 source' 33.13 is
! pointing to bit status when fan is running i.e. P.5.22.11.
! @image orm_abb_acs880_param_setting3.gif
!
!
......@@ -53005,6 +53009,11 @@ if (I1 >= 0 && I1 <= 9) {
EndObject
!/**
! Alarm text converter internal fan need maintenance.
!
! Reset alarm 'change fan' in the driver, see parameter 33.10
! 'On-time 1 actual' in the drivers control panel. The timer will
! be reset if the 'reset' are depressed for over 3 seconds in
! this parameter settings menu.
!*/
Object AlarmFanOld $Attribute 183 24-JUN-2013 10:53:43.33
Body SysBody 24-JUN-2013 10:53:43.33
......@@ -53219,7 +53228,7 @@ if (I1 >= 0 && I1 <= 9) {
EndObject
EndObject
Object Template ABB_ACS880_1 2159247360 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:54:36.95
Body RtBody 06-FEB-2014 16:03:46.20
Attr Specification = "ABB ACS880 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS880_PPO7_IoModule.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS880_PPO7_IoModule.I_IND"
......@@ -53281,7 +53290,12 @@ if (I1 >= 0 && I1 <= 9) {
Attr AlarmFanOld.EventType = 64
Attr AlarmFanOld.EventPriority = 66
Attr AlarmFanOld.EventFlags = 7
Attr AlarmFanOld.MoreText = ""
Attr AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880_1-Template"
Attr AlarmFanOld.CtrlPosition = 1
Attr AlarmFanOld.LockAttribute = 1
......@@ -69609,6 +69623,8 @@ bit 10 (d11) replace fan"
! input RefSpeedLoc [RLO] in local mode, or internal via graph (OpRefMan) in manual mode.
!
! @b Example PLC code for ACS880 aggregate
! Note if a contactor with start and stop pulse is used and input pin 'pil' Power Interlock
! goes low/false a stop pulse is generated.
! @image orm_abb_acs880_example6.gif
!
! @b Profibus
......@@ -70554,7 +70570,7 @@ bit 10 (d11) replace fan"
EndObject
EndObject
Object Template ABB_ACS880MotorAggr 2160033792 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:55:22.23
Body RtBody 06-FEB-2014 16:04:44.33
Attr AlarmToOften.DetectOn = 1
Attr AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr AlarmToOften.EventType = 64
......@@ -70657,7 +70673,12 @@ bit 10 (d11) replace fan"
Attr ACS880.AlarmFanOld.EventType = 64
Attr ACS880.AlarmFanOld.EventPriority = 66
Attr ACS880.AlarmFanOld.EventFlags = 7
Attr ACS880.AlarmFanOld.MoreText = ""
Attr ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880MotorAggr-Template.ACS880"
Attr ACS880.AlarmFanOld.CtrlPosition = 1
Attr ACS880.AlarmFanOld.LockAttribute = 1
......@@ -81791,7 +81812,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880PumpAggr 2160820224 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:56:04.75
Body RtBody 06-FEB-2014 16:05:11.14
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
......@@ -81897,7 +81918,12 @@ ABB ACS880 Aggregate
Attr Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880PumpAggr-Template.Super.ACS880"
Attr Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -82161,7 +82187,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880FanAggr 2161082368 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:56:58.57
Body RtBody 06-FEB-2014 16:05:49.61
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
......@@ -82267,7 +82293,12 @@ ABB ACS880 Aggregate
Attr Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880FanAggr-Template.Super.ACS880"
Attr Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -82779,6 +82810,10 @@ ABB ACS880 Aggregate
!
! Parameter group 33 to 50 settings to be performed.
! NoteGroup 50 index 2 "comm loss func" is important.
! Warning message 'change fan' in the driver need some settings in
! parameter group 33. 'On-time 1 Warn limit 33.11 is set to two
! years run time (63072000 seconds). 'On-time 1 source' 33.13 is
! pointing to bit status when fan is running i.e. P.5.22.11.
! @image orm_abb_acs880_epl_param_setting3.gif
!
!
......@@ -82809,7 +82844,7 @@ ABB ACS880 Aggregate
! Every node in a Powerlink network must be configured in this openCONFIGURATOR
! tool. In a Proview project all Powerlink CN nodes memory mapping is a reflection
! of the memory mapping in a openCONFIGURATOR project.
!
!
! From the openCONFIGURATOR configuration a cdc file is generated. This file is
! used by the Powerlink stack to initialize the communication. The name of the
! cdc-file should be specified in hte Epl_MN object, attribute CDCfile. The default
......@@ -83209,7 +83244,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880_Epl_1 2161344512 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 11:00:21.59
Body RtBody 06-FEB-2014 16:06:22.07
Attr Super.Specification = "ABB ACS880 Frequency converter"
Attr Super.DisableInIdPar = 1
Attr Super.DisableInIndPar = 1
......@@ -83282,7 +83317,12 @@ ABB ACS880 Aggregate
Attr Super.AlarmFanOld.EventType = 64
Attr Super.AlarmFanOld.EventPriority = 66
Attr Super.AlarmFanOld.EventFlags = 7
Attr Super.AlarmFanOld.MoreText = ""
Attr Super.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880_Epl_1-Template"
Attr Super.AlarmFanOld.CtrlPosition = 1
Attr Super.AlarmFanOld.LockAttribute = 1
......@@ -83507,6 +83547,8 @@ ABB ACS880 Aggregate
! input RefSpeedLoc [RLO] in local mode, or internal via graph (OpRefMan) in manual mode.
!
! @b Example PLC code for ACS880 aggregate
! Note if a contactor with start and stop pulse is used and input pin 'pil' Power Interlock
! goes low/false a stop pulse is generated.
! @image orm_abb_acs880_example6.gif
!
! @b Powerlink
......@@ -84096,7 +84138,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880EplMotorAggr 2163441664 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:58:37.01
Body RtBody 06-FEB-2014 16:06:53.92
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
......@@ -84213,7 +84255,12 @@ ABB ACS880 Aggregate
Attr Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880EplMotorAggr-Template.Super.ACS880"
Attr Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -84482,7 +84529,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880EplPumpAggr 2163703808 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:59:10.71
Body RtBody 06-FEB-2014 16:07:19.28
Attr Super.Super.AlarmToOften.DetectOn = 1
Attr Super.Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.Super.AlarmToOften.EventType = 64
......@@ -84599,7 +84646,12 @@ ABB ACS880 Aggregate
Attr Super.Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880EplPumpAggr-Template.Super.Super.ACS880"
Attr Super.Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -84868,7 +84920,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880EplFanAggr 2163965952 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 10:59:45.84
Body RtBody 06-FEB-2014 16:07:46.60
Attr Super.Super.AlarmToOften.DetectOn = 1
Attr Super.Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.Super.AlarmToOften.EventType = 64
......@@ -84985,7 +85037,12 @@ ABB ACS880 Aggregate
Attr Super.Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880EplFanAggr-Template.Super.Super.ACS880"
Attr Super.Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -86011,6 +86068,11 @@ ABB ACS880 Aggregate
!
! @b Settings 3
! Parameter group 33 to 50 settings to be performed.
! Note Group 50 index 2 "comm loss func" is important.
! Warning message 'change fan' in the driver need some settings in
! parameter group 33. 'On-time 1 Warn limit 33.11 is set to two
! years run time (63072000 seconds). 'On-time 1 source' 33.13 is
! pointing to bit status when fan is running i.e. P.5.22.11.
! @image orm_abb_acs880_param_setting3.gif
!
!
......@@ -86378,7 +86440,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880_Pn_1 2165014528 13-JAN-2014 13:56:27.40
Body RtBody 27-JAN-2014 11:00:54.52
Body RtBody 06-FEB-2014 16:08:18.93
Attr Super.Specification = "ABB ACS880 Frequency converter"
Attr Super.DisableInIdPar = 1
Attr Super.DisableInIndPar = 1
......@@ -86451,7 +86513,12 @@ ABB ACS880 Aggregate
Attr Super.AlarmFanOld.EventType = 64
Attr Super.AlarmFanOld.EventPriority = 66
Attr Super.AlarmFanOld.EventFlags = 7
Attr Super.AlarmFanOld.MoreText = ""
Attr Super.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880_Pn_1-Template"
Attr Super.AlarmFanOld.CtrlPosition = 1
Attr Super.AlarmFanOld.LockAttribute = 1
......@@ -86676,6 +86743,8 @@ ABB ACS880 Aggregate
! input RefSpeedLoc [RLO] in local mode, or internal via graph (OpRefMan) in manual mode.
!
! @b Example PLC code for ACS880 aggregate
! Note if a contactor with start and stop pulse is used and input pin 'pil' Power Interlock
! goes low/false a stop pulse is generated.
! @image orm_abb_acs880_example6.gif
!
! @b Profinet
......@@ -87268,7 +87337,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880PnMotorAggr 2165538816 01-JAN-1970 01:00:00.00
Body RtBody 27-JAN-2014 11:01:24.83
Body RtBody 06-FEB-2014 16:08:42.31
Attr Super.AlarmToOften.DetectOn = 1
Attr Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.AlarmToOften.EventType = 64
......@@ -87386,7 +87455,12 @@ ABB ACS880 Aggregate
Attr Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880MotorAggr-Template.ACS880"
Attr Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -87661,7 +87735,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880PnPumpAggr 2165800960 23-JAN-2014 08:40:59.50
Body RtBody 27-JAN-2014 11:01:56.52
Body RtBody 06-FEB-2014 16:09:12.46
Attr Super.Super.AlarmToOften.DetectOn = 1
Attr Super.Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.Super.AlarmToOften.EventType = 64
......@@ -87778,7 +87852,12 @@ ABB ACS880 Aggregate
Attr Super.Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880PnPumpAggr-Template.Super.Super.ACS880"
Attr Super.Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -88053,7 +88132,7 @@ ABB ACS880 Aggregate
EndObject
EndObject
Object Template ABB_ACS880PnFanAggr 2166063104 23-JAN-2014 08:42:42.17
Body RtBody 27-JAN-2014 11:02:33.91
Body RtBody 06-FEB-2014 16:09:49.49
Attr Super.Super.AlarmToOften.DetectOn = 1
Attr Super.Super.AlarmToOften.DetectText = "Power not yet ready for restart, wait before retry"
Attr Super.Super.AlarmToOften.EventType = 64
......@@ -88170,7 +88249,12 @@ ABB ACS880 Aggregate
Attr Super.Super.ACS880.AlarmFanOld.EventType = 64
Attr Super.Super.ACS880.AlarmFanOld.EventPriority = 66
Attr Super.Super.ACS880.AlarmFanOld.EventFlags = 7
Attr Super.Super.ACS880.AlarmFanOld.MoreText = ""
Attr Super.Super.ACS880.AlarmFanOld.MoreText = "Check the drivers internal fan.
Reset alarm 'change fan' in the driver, see parameter 33.10
'On-time 1 actual' in the drivers control panel. The timer will
be reset if the 'reset' are depressed for over 3 seconds in
this parameter settings menu."
Attr Super.Super.ACS880.AlarmFanOld.Attribute = "ABB:Class-ABB_ACS880PnFanAggr-Template.Super.Super.ACS880"
Attr Super.Super.ACS880.AlarmFanOld.CtrlPosition = 1
Attr Super.Super.ACS880.AlarmFanOld.LockAttribute = 1
......@@ -50611,7 +50611,7 @@ Alarm HH, H, L, LL"
!
! @b Example 11 Settings in Proview node CN
! Settings needed in Proview for class Epl_CN. The 'NodeId'
! shall be the same as in the openCONFIGURATOR, i.e 15, see
! shall be the same as in the openCONFIGURATOR, i.e. 15, see
! also example 15 below.
!
! @image orm_br_proview_cn_node_settings.gif
......@@ -50685,15 +50685,17 @@ Alarm HH, H, L, LL"
!
!
! @bExample 16
! Memory mapping settings TPDO, reads data from the B&R bus controller, i.e Power Supply,
! Di and Ai in this order. For example the yellow marked address 0x2102 is the
! address specification for analog input X20AI4632.
! Memory mapping settings TPDO, reads data from the B&R bus controller, i.e. Power Supply,
! Di, Ai and Ao in this order. For example the yellow marked address 0x2102 is the
! address specification for analog input X20AI4632 slot ST3. Note that the Ao unit
! X20AO4632(0x2003) slot ST4 also is mapped here becouse the unit have one input ChanIi
! ChanNetworkStatus attribute.
! @image orm_br_open_conf_input_mapping.gif
!
!
! @bExample 17
! Memory mapping settings RPDO, writes data to the B&R bus controller, i.e Ao word. The
! yellow marked address 0x2103 is the analog output X20AO4632.
! Memory mapping settings RPDO, writes data to the B&R bus controller, i.e. Ao word. The
! yellow marked address 0x2103 is the analog output X20AO4632 slot ST4.
! @image orm_br_open_conf_output_mapping.gif
!
!