; (c) 2006 Siemens AG A&D SD
;
; Profibus-DP Generic Station Description for SINAMICS G120 Safety incl. PROFIsafe
;
; MLFB: 6SL3244-0BA21-1PA0 (G120 CU240S DP F)
;
; Author: SIEMENS AG A&D SD
;
; Date of Creation: 11.03.2006 Initial version
; Changes:
; 10.11.2006 model_name changed; new module 353 and 354; software_release changed
; 05.01.2007 add version to model_Name and info_text; filename changed to SI028116
; 17.07.2007 F_IO_StructureDescCRC=5639 added
;
;==========================================================================
;
;*********************** general keys
;
#Profibus_DP
;
GSD_Revision=5
Vendor_Name="Siemens AG A&D"
Model_Name="SINAMICS G120 CU240S DP F v3.00"
Info_Text="DP-Slave SINAMICS G120 CU240S DP F v3.00 safety variant with PROFIsafe v1.x and DP-V1 interface (cyclic and acyclic communication)."
Revision="C01"
Ident_Number=0x8158
Protocol_Ident=0 ; 0 = PROFIBUS-DP
Station_Type=0 ; 0 = DP-Slave
FMS_supp=0 ; no FMS / DP mixed device
Hardware_Release="C01"
Software_Release="V03.0"
;
OrderNumber="6SL3 244-0BA21-1PA0"
;
;supported baudrates
9.6_supp=1
19.2_supp=1
45.45_supp=1
93.75_supp=1
187.5_supp=1
500_supp=1
1.5M_supp=1
3M_supp=1
6M_supp=1
12M_supp=1
;
;maximum station delaytime of responder at corresponding baudrate
MaxTsdr_9.6=40
MaxTsdr_19.2=40
MaxTsdr_45.45=40
MaxTsdr_93.75=40
MaxTsdr_187.5=40
MaxTsdr_500=40
MaxTsdr_1.5M=40
MaxTsdr_3M=50
MaxTsdr_6M=100
MaxTsdr_12M=200
;
Redundancy=0 ; not supported
Repeater_Ctrl_Sig=2 ; TTL
24V_Pins=0 ; no 24 Volt
Implementation_Type="DPC31"
Bitmap_Device="SI028158"
;*********************** slave basic ---
Freeze_Mode_supp=1
Sync_Mode_supp=1
Auto_Baud_supp=1
Set_Slave_Add_supp=0
;
Max_User_Prm_Data_Len=36 ;max. length of param tele
Min_Slave_Intervall=1 ; = 100 s
Modular_Station=1
Max_Module=2
Max_Input_Len=32
Max_Output_Len=32
Max_Data_Len=64
Fail_Safe=1
Max_Diag_Data_Len=48
Modul_Offset=1
Slave_Family=1@SINAMICS
;
;*********************** (GSD R5)
Ident_Maintenance_supp=1
;
;*********************** Text defines
;PrmText=1
;Text(0)="No"
;Text(1)="Yes"
;EndPrmText
PrmText=2
;Text(0)="SIL 1"
Text(1)="SIL 2"
;Text(2)="SIL 3"
;Text(3)="NoSIL"
EndPrmText
PrmText=3
Text(0)="No Check"
;Text(1)="Check"
EndPrmText
;Text-Definition fuer CRC-Length
PrmText=4
;Text(0)="reserved"
Text(1)="2 Byte CRC"
;Text(2)="4 Byte CRC"
;Text(3)="reserved 1"
EndPrmText
;*********************** Ext-User-Prm-Data-Def-List
ExtUserPrmData=1 "F_Check_SeqNr" ; Reference number 1
Bit(0) 0 0-0 ; Default = 0
Prm_Text_Ref=3 ; Pointer to text definition 3
EndExtUserPrmData
ExtUserPrmData=2 "F_SIL"
BitArea(2-3) 1 1-1
Prm_Text_Ref=2
EndExtUserPrmData
ExtUserPrmData=3 "F_CRC_Length"
BitArea(4-5) 1 1-1
Prm_Text_Ref=4
EndExtUserPrmData
ExtUserPrmData=4 "F_Par_Version"
BitArea(6-7) 0 0-0
EndExtUserPrmData
ExtUserPrmData=5 "F_Source_Add"
Unsigned16 1 1-65534
EndExtUserPrmData
ExtUserPrmData=6 "F_Dest_Add"
Unsigned16 1 1-65534
EndExtUserPrmData
ExtUserPrmData=7 "F_WD_Time"
Unsigned16 100 10-65535
EndExtUserPrmData
ExtUserPrmData=8 "F_Par_CRC"
Unsigned16 0x783E 0-65535
EndExtUserPrmData
ExtUserPrmData=10 "[SlotNumber]"
Unsigned8 1 1-254 ; Default = 1, Max = 254
EndExtUserPrmData
;*********************** diagnose
UnitDiagType = 129
X_Unit_Diag_Area=24-31
X_Value(64) = "F add. does not match F_Dest_Add"
X_Value(65) = "Wrong F destination address"
X_Value(66) = "Wrong F source address"
X_Value(67) = "Watchdog time value=0"
X_Value(68) = "Wrong SIL level"
X_Value(69) = "Wrong F-CRC length"
X_Value(70) = "Wrong F-Parameter version"
X_Value(71) = "CRC1 fault"
X_Value(72) = "reserved"
X_Value(73) = "reserved"
X_Value(74) = "reserved"
X_Unit_Diag_Area_End
EndUnitDiagType
;
;*********************** slave related keywords for extended parameterization (GSD V4)
Ext_User_Prm_Data_Const(0)=0 ;DPV1 state 1
Ext_User_Prm_Data_Const(1)=0 ;DPV1 state 2
Ext_User_Prm_Data_Const(2)=0 ;DPV1 state 3
;
;*********************** slave extensions (GSD R3)
DPV1_Slave=1
;
C1_Read_Write_supp=1
C2_Read_Write_supp=1
C1_Max_Data_Len=240
C2_Max_Data_Len=240
C1_Response_Timeout=1 ;Timebase 10ms
C2_Response_Timeout=1 ;Timebase 10ms
C1_Read_Write_required=0
C2_Read_Write_required=0
C2_Max_Count_Channels=2
Max_Initiate_PDU_Length=52
WD_Base_1ms_supp=1
;
DPV1_Data_Types=0
Check_Cfg_Mode=0
;
;*********************** slave data exchange broadcast
Publisher_supp=0
;Subscriber_supp=0
;if Subscriber = 1
;X_PRM_SAP_supp=1
;X_Max_User_Prm_Data_Len=20
;X_Prm_Block_Structure_supp=1
;
;DXB_Max_Link_Count=10
;DXB_Max_Data_Length=40
;DXB_Subscribertable_Block_Location=1
;
;*********************** slave data exchange Isochron
;Isochron_Mode_supp=1
;Isochron_Mode_required=0
; do not specify this parameters if Isochron_mode_supp=0
;TBase_DP=1500 ; 125 s (1500/12)
;TDP_Max=256 ; 32 ms (256*TBase_DP) 32ms is maximum
;TDP_Min=16 ; 2 ms ( 16*TBase_DP)
;TBase_IO=1500 ; 125 s (1500/12)
;TI_Min=1 ; 125 s ( 1*TBase_IO)
;TO_Min=1 ; 125 s ( 1*TBase_IO)
;T_PLL_W_MAX=12 ; 1 s ( 12/12)
;
;*********************** module definitions
;
;=======================================
Module="Standard telegram 1" 0xE1, 0xD1
1
Info_Text="Standard telegram 1 (PZD-2/2) according to PROFIdrive V4. 2 words output and 2 words input"
EndModule
;=======================================
Module="Standard telegram 20" 0xE1, 0xD5
2
Info_Text="Standard telegram 20 (PZD-2/6) according to PROFIdrive V4. 2 words output and 6 words input."
EndModule
;=======================================
Module="SIEMENS telegram 350" 0xE3, 0xD3
3
Info_Text="SIEMENS specific telegram 350 (PZD-4/4). 4 words output and 4 words input."
EndModule
;=======================================
Module="SIEMENS telegram 352" 0xE5, 0xD5
4
Info_Text="SIEMENS specific telegram 352 (PZD-6/6). 6 words output and 6 words input. Output words 3-6 defined as PCS7 handled data."
EndModule
;=======================================
;Module="SIEMENS telegram 353" 0xF3, 0xE1, 0xD1
Module="SIEMENS telegram 353" 0xf3, 0xc3, 0xc1, 0xc1, 0xfd, 0x01, 0x61
5
Info_Text="SIEMENS specific telegram 353 (PKW-4/4 + PZD-2/2). PKW data with 4 words input and 4 words output. PZD data with 2 words output and 2 words input."
EndModule
;=======================================
;Module="SIEMENS telegram 354" 0xF3, 0xE5, 0xD5
Module="SIEMENS telegram 354" 0xf3, 0xc3, 0xc5, 0xc5, 0xfd, 0x01, 0x62
6
Info_Text="SIEMENS specific telegram 354 (PKW-4/4 + PZD 6/6). PKW data with 4 words input and 4 words output. PZD data with 6 words output and 6 words input, outputwords 3-6 are defined as PCS7 data."
EndModule
;=======================================
Module="PROFIsafe v1.x Module" 0xC6,0x85,0x85,0x05,0x05,0x0a,0x05,0x05,0x0a
7
Info_Text = "PROFIsafe v1.x module, take care on Dest_Adr"
F_Ext_Module_Prm_Data_Len=14
F_Ext_User_Prm_Data_Const(0)=0xE ;length of block F-Parameter
F_Ext_User_Prm_Data_Const(1)=5 ;sign F-Parameter
F_Ext_User_Prm_Data_Ref(2)=10 ;auto slot number F-Moduls
F_Ext_User_Prm_Data_Const(3)=0 ;specifier
F_Ext_User_Prm_Data_Const(4)=0 ;F-Param-Flag 1 default 0x14
F_Ext_User_Prm_Data_Const(5)=0 ;F-Param-Flag 2 default 0x00
F_Ext_User_Prm_Data_Ref(4)=1 ;F-Param 1 Bit 0 CheckSeqNr = 0
F_Ext_User_Prm_Data_Ref(4)=2 ;F-Param 1 Bit 2-3 SIL = 1
F_Ext_User_Prm_Data_Ref(4)=3 ;F-Param 1 Bit 4-5 CRC Length = 2 Byte
F_Ext_User_Prm_Data_Ref(5)=4 ;F-Param 2 Bit 6-7 Par Version = 0
F_Ext_User_Prm_Data_Ref(6)=5 ;F-Source-Adr
F_Ext_User_Prm_Data_Ref(8)=6 ;F-Dest-Adr
F_Ext_User_Prm_Data_Ref(10)=7 ;F-WD-Time
F_Ext_User_Prm_Data_Ref(12)=8 ;F-CRC1
;The value of this parameter will not be transferred to the slave device but is
;needed to avoid errors during the parametrization with the configuration tool.
F_ParamDescCRC=0xA01D
F_IO_StructureDescCRC=5639
EndModule
;=======================================