Commit c71c2b13 authored by claes's avatar claes

Alarm text changes, and motor default config

parent 5d193048
...@@ -843,7 +843,7 @@ Volume ABB $ClassVolume 0.0.250.2 ...@@ -843,7 +843,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject EndObject
EndObject EndObject
Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00 Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00
Body RtBody 06-DEC-2005 16:04:23.58 Body RtBody 23-JAN-2006 09:27:06.19
Attr Specification = "ABB ACS800 Frequency converter" Attr Specification = "ABB ACS800 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_ID" Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_IND" Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_IND"
...@@ -867,9 +867,9 @@ Volume ABB $ClassVolume 0.0.250.2 ...@@ -867,9 +867,9 @@ Volume ABB $ClassVolume 0.0.250.2
Attr RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF" Attr RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr RefSpeed.DefTrend = "ABB:Class-ABB_ACS800_1-Template.TrendRefSpeed" Attr RefSpeed.DefTrend = "ABB:Class-ABB_ACS800_1-Template.TrendRefSpeed"
Attr PowerUpTime = 1.500000e+01 Attr PowerUpTime = 1.500000e+01
Attr AlarmLocalMod = "Frequency converter control location is local, " Attr AlarmLocalMod = "Frequency converter is in local mode, "
Attr AlarmTripped = "Frequency converter tripped, you must reset, " Attr AlarmTripped = "Frequency converter tripped, reset is required, "
Attr AlarmFanOld = "Replace cooling fan in frequency converter, " Attr AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr AlarmWarning = "Frequency converter warning, " Attr AlarmWarning = "Frequency converter warning, "
Attr AlarmError = "Frequency converter error, " Attr AlarmError = "Frequency converter error, "
Attr DefTrend = "ABB:Class-ABB_ACS800_1-Template.PlotGroup" Attr DefTrend = "ABB:Class-ABB_ACS800_1-Template.PlotGroup"
...@@ -11929,10 +11929,10 @@ ABB ACS800 Typ 1" ...@@ -11929,10 +11929,10 @@ ABB ACS800 Typ 1"
EndObject EndObject
EndObject EndObject
Object Template ABB_ACS800MotorAggr 2148761600 12-OCT-2005 12:58:20.00 Object Template ABB_ACS800MotorAggr 2148761600 12-OCT-2005 12:58:20.00
Body RtBody 06-DEC-2005 16:07:32.85 Body RtBody 23-JAN-2006 09:29:23.78
Attr AlarmTextToOften = "Start up converter (power on) to often, wait before try again " Attr AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed " Attr AlarmTextPowOnNotOk = "Power interlocked, "
Attr AlarmTextStartNoOk = "Power is not on, start is not allowed " Attr AlarmTextStartNoOk = "Power is not on, "
Attr CircuitBreaker.AlarmText = "Circuit breaker tripped, " Attr CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Contactor.FbTimeLimit = 1.000000e+00 Attr Contactor.FbTimeLimit = 1.000000e+00
Attr Contactor.AlarmText = "Feedback contactor lost, " Attr Contactor.AlarmText = "Feedback contactor lost, "
...@@ -11960,9 +11960,9 @@ ABB ACS800 Typ 1" ...@@ -11960,9 +11960,9 @@ ABB ACS800 Typ 1"
Attr ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF" Attr ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr ACS800.RefSpeed.PresMaxLimit = 2.000000e+03 Attr ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr ACS800.PowerUpTime = 1.500000e+01 Attr ACS800.PowerUpTime = 1.500000e+01
Attr ACS800.AlarmLocalMod = "Frequency converter control location is local, " Attr ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr ACS800.AlarmTripped = "Frequency converter tripped, you must reset, " Attr ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, " Attr ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr ACS800.AlarmWarning = "Frequency converter warning, " Attr ACS800.AlarmWarning = "Frequency converter warning, "
Attr ACS800.AlarmError = "Frequency converter error, " Attr ACS800.AlarmError = "Frequency converter error, "
Attr ACS800.DefTrend = "ABB:Class-ABB_ACS800MotorAggr-Template.ACS800.PlotGroup" Attr ACS800.DefTrend = "ABB:Class-ABB_ACS800MotorAggr-Template.ACS800.PlotGroup"
...@@ -12003,6 +12003,9 @@ ABB ACS800 Typ 1" ...@@ -12003,6 +12003,9 @@ ABB ACS800 Typ 1"
Attr ACS800.PlotGroup.YUnit[2] = "A" Attr ACS800.PlotGroup.YUnit[2] = "A"
Attr ACS800.PlotGroup.NumPoints = 478 Attr ACS800.PlotGroup.NumPoints = 478
Attr SafetySwitch.AlarmText = "Safety switch is off, " Attr SafetySwitch.AlarmText = "Safety switch is off, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1 Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1 Attr Motor.TempSensor.Super.DisableValue = 1
...@@ -21871,10 +21874,10 @@ ABB ACS800 Aggregate ...@@ -21871,10 +21874,10 @@ ABB ACS800 Aggregate
EndObject EndObject
EndObject EndObject
Object Template ABB_ACS800PumpAggr 2151120896 01-JAN-1970 01:00:00.00 Object Template ABB_ACS800PumpAggr 2151120896 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 16:21:15.77 Body RtBody 23-JAN-2006 09:29:54.52
Attr Super.AlarmTextToOften = "Start up converter (power on) to often, wait before try again " Attr Super.AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr Super.AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed " Attr Super.AlarmTextPowOnNotOk = "Power interlocked, "
Attr Super.AlarmTextStartNoOk = "Power is not on, start is not allowed " Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, " Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00 Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, " Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...@@ -21885,9 +21888,9 @@ ABB ACS800 Aggregate ...@@ -21885,9 +21888,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.ActCurrent.PresMaxLimit = 5.000000e+01 Attr Super.ACS800.ActCurrent.PresMaxLimit = 5.000000e+01
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03 Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01 Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter control location is local, " Attr Super.ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, you must reset, " Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr Super.ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, " Attr Super.ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, " Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, " Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800PumpAggr-Template.Super.ACS800.PlotGroup" Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800PumpAggr-Template.Super.ACS800.PlotGroup"
...@@ -21928,6 +21931,9 @@ ABB ACS800 Aggregate ...@@ -21928,6 +21931,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A" Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478 Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, " Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1 Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1 Attr Super.Motor.TempSensor.Super.DisableValue = 1
...@@ -22046,10 +22052,10 @@ ABB ACS800 Aggregate ...@@ -22046,10 +22052,10 @@ ABB ACS800 Aggregate
EndObject EndObject
EndObject EndObject
Object Template ABB_ACS800FanAggr 2151383040 01-JAN-1970 01:00:00.00 Object Template ABB_ACS800FanAggr 2151383040 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 16:23:59.95 Body RtBody 23-JAN-2006 09:30:28.13
Attr Super.AlarmTextToOften = "Start up converter (power on) to often, wait before try again " Attr Super.AlarmTextToOften = "Power not yet ready for restart, wait before retry, "
Attr Super.AlarmTextPowOnNotOk = "Check interlocks! Start up (power on) converter is not allowed " Attr Super.AlarmTextPowOnNotOk = "Power interlocked, "
Attr Super.AlarmTextStartNoOk = "Power is not on, start is not allowed " Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, " Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00 Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, " Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...@@ -22077,9 +22083,9 @@ ABB ACS800 Aggregate ...@@ -22077,9 +22083,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF" Attr Super.ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03 Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01 Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter control location is local, " Attr Super.ACS800.AlarmLocalMod = "Frequency converter is in local mode, "
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, you must reset, " Attr Super.ACS800.AlarmTripped = "Frequency converter tripped, reset is required, "
Attr Super.ACS800.AlarmFanOld = "Replace cooling fan in frequency converter, " Attr Super.ACS800.AlarmFanOld = "Maintenance replace of cooling fan in converter required, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, " Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, " Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800FanAggr-Template.Super.ACS800.PlotGroup" Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800FanAggr-Template.Super.ACS800.PlotGroup"
...@@ -22120,6 +22126,9 @@ ABB ACS800 Aggregate ...@@ -22120,6 +22126,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A" Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478 Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, " Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1 Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1 Attr Super.Motor.TempSensor.Super.DisableValue = 1
...@@ -22201,7 +22210,7 @@ ABB ACS800 Aggregate ...@@ -22201,7 +22210,7 @@ ABB ACS800 Aggregate
! signal r i sin tur knuten till signalnamnet "ActTorque" i objektet ! signal r i sin tur knuten till signalnamnet "ActTorque" i objektet
! "ABB_ACS800_1". ! "ABB_ACS800_1".
! !
! OBS! ! OBS
! vriga instllningar i omriktaren som mste till fr en fungerande ! vriga instllningar i omriktaren som mste till fr en fungerande
! kommunikation beaktas inte hr. ! kommunikation beaktas inte hr.
! !
......
...@@ -57885,11 +57885,12 @@ Alarm HH, H, L, LL" ...@@ -57885,11 +57885,12 @@ Alarm HH, H, L, LL"
EndObject EndObject
EndObject EndObject
Object Template BaseActuatorA 2176286720 01-JAN-1970 01:00:00.00 Object Template BaseActuatorA 2176286720 01-JAN-1970 01:00:00.00
Body RtBody 03-OCT-2005 14:10:42.58 Body RtBody 23-JAN-2006 09:31:54.36
Attr Order.Unit = "%" Attr Order.Unit = "%"
Attr Order.PresMaxLimit = 1.000000e+02 Attr Order.PresMaxLimit = 1.000000e+02
Attr Position.PresMaxLimit = 1.000000e+02 Attr Position.PresMaxLimit = 1.000000e+02
Attr Mode.OpNoLocal = 1 Attr Mode.OpNoLocal = 1
Attr Mode.OpMaxRefMan = 1.000000e+02
Attr Mode.AlarmLocalMode = "Local mode is activated, " Attr Mode.AlarmLocalMode = "Local mode is activated, "
Attr MaxPosDiff = 5.000000e+00 Attr MaxPosDiff = 5.000000e+00
Attr DiffAlarmDelay = 1.000000e+01 Attr DiffAlarmDelay = 1.000000e+01
...@@ -66517,12 +66518,13 @@ Alarm HH, H, L, LL" ...@@ -66517,12 +66518,13 @@ Alarm HH, H, L, LL"
EndObject EndObject
EndObject EndObject
Object Template BaseCValve 2177073152 01-JAN-1970 01:00:00.00 Object Template BaseCValve 2177073152 01-JAN-1970 01:00:00.00
Body RtBody 03-OCT-2005 14:10:21.13 Body RtBody 23-JAN-2006 09:34:07.12
Attr Actuator.GraphConfiguration = 4 Attr Actuator.GraphConfiguration = 4
Attr Actuator.Order.Unit = "%" Attr Actuator.Order.Unit = "%"
Attr Actuator.Order.PresMaxLimit = 1.000000e+02 Attr Actuator.Order.PresMaxLimit = 1.000000e+02
Attr Actuator.Position.PresMaxLimit = 1.000000e+02 Attr Actuator.Position.PresMaxLimit = 1.000000e+02
Attr Actuator.Mode.OpNoLocal = 1 Attr Actuator.Mode.OpNoLocal = 1
Attr Actuator.Mode.OpMaxRefMan = 1.000000e+02
Attr Actuator.Mode.AlarmLocalMode = "Local mode is activated, " Attr Actuator.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Actuator.MaxPosDiff = 5.000000e+00 Attr Actuator.MaxPosDiff = 5.000000e+00
Attr Actuator.DiffAlarmDelay = 1.000000e+01 Attr Actuator.DiffAlarmDelay = 1.000000e+01
...@@ -77365,7 +77367,10 @@ Alarm HH, H, L, LL" ...@@ -77365,7 +77367,10 @@ Alarm HH, H, L, LL"
EndObject EndObject
EndObject EndObject
Object Template BaseMotor 2177859584 01-JAN-1970 01:00:00.00 Object Template BaseMotor 2177859584 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:56:14.11 Body RtBody 23-JAN-2006 09:32:17.05
Attr GraphConfiguration = 2
Attr DisableTempSwitch = 1
Attr TempSwitch.Super.DisableSwitch = 1
Attr TempSwitch.Super.AlarmText = "High motor temperature, " Attr TempSwitch.Super.AlarmText = "High motor temperature, "
Attr DisableTempSensor = 1 Attr DisableTempSensor = 1
Attr TempSensor.Super.DisableValue = 1 Attr TempSensor.Super.DisableValue = 1
...@@ -89907,7 +89912,7 @@ Safety switch" ...@@ -89907,7 +89912,7 @@ Safety switch"
EndObject EndObject
EndObject EndObject
Object Template BaseMotorAggr 2182316032 01-JAN-1970 01:00:00.00 Object Template BaseMotorAggr 2182316032 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:57:09.70 Body RtBody 23-JAN-2006 09:32:37.70
Attr Contactor.Order.Description = "Energize contactor" Attr Contactor.Order.Description = "Energize contactor"
Attr Contactor.Feedback.Description = "Contactor is energized" Attr Contactor.Feedback.Description = "Contactor is energized"
Attr Contactor.FbTimeLimit = 1.000000e+00 Attr Contactor.FbTimeLimit = 1.000000e+00
...@@ -89921,8 +89926,12 @@ Safety switch" ...@@ -89921,8 +89926,12 @@ Safety switch"
Attr Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, " Attr Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Mode.Alarm2LocalMod = "Local mode is activated, " Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, " Attr Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1 Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
Attr Motor.TempSensor.Super.Value.Unit = "C" Attr Motor.TempSensor.Super.Value.Unit = "C"
Attr Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02 Attr Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, " Attr Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...@@ -95266,7 +95275,7 @@ Motor aggregat" ...@@ -95266,7 +95275,7 @@ Motor aggregat"
EndObject EndObject
EndObject EndObject
Object Template BaseFanAggr 2183364608 01-JAN-1970 01:00:00.00 Object Template BaseFanAggr 2183364608 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:58:47.74 Body RtBody 23-JAN-2006 09:32:57.88
Attr Super.Contactor.Order.Description = "Energize contactor" Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized" Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00 Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...@@ -95280,8 +95289,12 @@ Motor aggregat" ...@@ -95280,8 +95289,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, " Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, " Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, " Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1 Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C" Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02 Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, " Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...@@ -95380,7 +95393,7 @@ Motor aggregat" ...@@ -95380,7 +95393,7 @@ Motor aggregat"
EndObject EndObject
EndObject EndObject
Object Template BasePumpAggr 2184675328 01-JAN-1970 01:00:00.00 Object Template BasePumpAggr 2184675328 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:58:11.81 Body RtBody 23-JAN-2006 09:33:14.26
Attr Super.Contactor.Order.Description = "Energize contactor" Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized" Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00 Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...@@ -95394,8 +95407,12 @@ Motor aggregat" ...@@ -95394,8 +95407,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, " Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, " Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, " Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1 Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C" Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02 Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, " Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...@@ -96168,7 +96185,7 @@ Motor aggregat" ...@@ -96168,7 +96185,7 @@ Motor aggregat"
EndObject EndObject
EndObject EndObject
Object Template BaseMotorIncrDecrAggr 2185199616 01-JAN-1970 01:00:00.00 Object Template BaseMotorIncrDecrAggr 2185199616 01-JAN-1970 01:00:00.00
Body RtBody 16-DEC-2005 15:56:50.10 Body RtBody 23-JAN-2006 09:33:39.14
Attr ContactorIncr.Order.Description = "Energize contactor" Attr ContactorIncr.Order.Description = "Energize contactor"
Attr ContactorIncr.Feedback.Description = "Contactor is energized" Attr ContactorIncr.Feedback.Description = "Contactor is energized"
Attr ContactorIncr.FbTimeLimit = 1.000000e+00 Attr ContactorIncr.FbTimeLimit = 1.000000e+00
...@@ -96188,6 +96205,9 @@ Motor aggregat" ...@@ -96188,6 +96205,9 @@ Motor aggregat"
Attr Mode.Alarm2LocalMod = "Local mode is activated, " Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual order is not allowed, " Attr Mode.AlarmNotManOrd = "Automode active. Manual order is not allowed, "
Attr Mode.AlarmOrderTimeOut = "Timeout, limit switch not reached, " Attr Mode.AlarmOrderTimeOut = "Timeout, limit switch not reached, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, " Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1 Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1 Attr Motor.TempSensor.Super.DisableValue = 1
...@@ -38,12 +38,12 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -38,12 +38,12 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject EndObject
EndObject EndObject
Object Template Ventim_Valve_VM3001 2147975168 06-OCT-2005 09:28:20.00 Object Template Ventim_Valve_VM3001 2147975168 06-OCT-2005 09:28:20.00
Body RtBody 01-JAN-1970 01:00:00.00 Body RtBody 23-JAN-2006 09:22:29.15
Attr Super.Super.Specification = "Ventim Butterfly valve VM3001" Attr Super.Super.Specification = "Ventim Butterfly valve VM3001"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/ventim_valve_vm3001.pdf" Attr Super.Super.DataSheet = "$pwr_lang/dsh/ventim_valve_vm3001.pdf"
Attr Super.SwitchOpen.Description = "Valve is open" Attr Super.SwitchOpen.Description = "Valve is open"
Attr Super.SwitchClosed.Description = "Valve is closed" Attr Super.SwitchClosed.Description = "Valve is closed"
Attr Super.AlarmText = "Valve error" Attr Super.AlarmText = "Valve error, "
EndBody EndBody
EndObject EndObject
EndObject EndObject
...@@ -118,7 +118,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -118,7 +118,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject EndObject
EndObject EndObject
Object Template Bernard_Actuator_OA 2150858752 06-OCT-2005 09:28:20.00 Object Template Bernard_Actuator_OA 2150858752 06-OCT-2005 09:28:20.00
Body RtBody 06-OCT-2005 09:45:37.69 Body RtBody 23-JAN-2006 09:25:04.66
Attr Super.Super.Specification = "Bernard stlldon typ OA" Attr Super.Super.Specification = "Bernard stlldon typ OA"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/bernard_actuator_oa.html" Attr Super.Super.DataSheet = "$pwr_lang/dsh/bernard_actuator_oa.html"
Attr Super.GraphConfiguration = 4 Attr Super.GraphConfiguration = 4
...@@ -127,6 +127,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -127,6 +127,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Position.Unit = "%" Attr Super.Position.Unit = "%"
Attr Super.Position.PresMaxLimit = 1.000000e+02 Attr Super.Position.PresMaxLimit = 1.000000e+02
Attr Super.Mode.OpNoLocal = 1 Attr Super.Mode.OpNoLocal = 1
Attr Super.Mode.OpMaxRefMan = 1.000000e+02
Attr Super.Mode.AlarmLocalMode = "Local mode is activated, " Attr Super.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Super.MaxPosDiff = 5.000000e+00 Attr Super.MaxPosDiff = 5.000000e+00
Attr Super.DiffAlarmDelay = 1.000000e+01 Attr Super.DiffAlarmDelay = 1.000000e+01
...@@ -249,9 +250,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -249,9 +250,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01 Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor " Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01 Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, levelsensor " Attr Super.Super.LimitL.AlarmText = "Below Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01 Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, levelsensor " Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00 Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1 Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Impac_TempSensor_IN300-Template.Super.Super.Value.ActualValue" Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Impac_TempSensor_IN300-Template.Super.Super.Value.ActualValue"
...@@ -377,9 +378,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -377,9 +378,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01 Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor " Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01 Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, levelsensor " Attr Super.Super.LimitL.AlarmText = "Below Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01 Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, levelsensor " Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00 Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1 Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Mobrey_LevelSensor_MSP422-Template.Super.Super.Value.ActualValue" Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Mobrey_LevelSensor_MSP422-Template.Super.Super.Value.ActualValue"
...@@ -467,9 +468,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1 ...@@ -467,9 +468,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01 Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, pressuresensor " Attr Super.Super.LimitH.AlarmText = "High limit exceeded, pressuresensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01 Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Beyond Low limit, pressuresensor " Attr Super.Super.LimitL.AlarmText = "Below Low limit, pressuresensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01 Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Beyond LowLow limit, pressuresensor " Attr Super.Super.LimitLL.AlarmText = "Below LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00 Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1 Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Klay_PressureSensor_Series2000-Template.Super.Super.Value.ActualValue" Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Klay_PressureSensor_Series2000-Template.Super.Super.Value.ActualValue"
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment