Skip to content
Projects
Groups
Snippets
Help
Loading...
Help
Support
Keyboard shortcuts
?
Submit feedback
Contribute to GitLab
Sign in / Register
Toggle navigation
P
proview
Project overview
Project overview
Details
Activity
Releases
Repository
Repository
Files
Commits
Branches
Tags
Contributors
Graph
Compare
Issues
0
Issues
0
List
Boards
Labels
Milestones
Merge Requests
0
Merge Requests
0
CI / CD
CI / CD
Pipelines
Jobs
Schedules
Analytics
Analytics
CI / CD
Repository
Value Stream
Wiki
Wiki
Snippets
Snippets
Members
Members
Collapse sidebar
Close sidebar
Activity
Graph
Create a new issue
Jobs
Commits
Issue Boards
Open sidebar
Esteban Blanc
proview
Commits
c71c2b13
Commit
c71c2b13
authored
Jan 23, 2006
by
claes
Browse files
Options
Browse Files
Download
Email Patches
Plain Diff
Alarm text changes, and motor default config
parent
5d193048
Changes
3
Show whitespace changes
Inline
Side-by-side
Showing
3 changed files
with
139 additions
and
109 deletions
+139
-109
abb/wbl/mcomp/src/abb.wb_load
abb/wbl/mcomp/src/abb.wb_load
+102
-93
bcomp/wbl/bcomp/src/basecomponent.wb_load
bcomp/wbl/bcomp/src/basecomponent.wb_load
+27
-7
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
+10
-9
No files found.
abb/wbl/mcomp/src/abb.wb_load
View file @
c71c2b13
...
...
@@ -843,7 +843,7 @@ Volume ABB $ClassVolume 0.0.250.2
EndObject
EndObject
Object Template ABB_ACS800_1 2148237312 12-OCT-2005 12:58:20.00
Body RtBody
06-DEC-2005 16:04:23.58
Body RtBody
23-JAN-2006 09:27:06.19
Attr Specification = "ABB ACS800 Frequency converter"
Attr InIdPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_ID"
Attr InIndPar.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.I_IND"
...
...
@@ -867,9 +867,9 @@ Volume ABB $ClassVolume 0.0.250.2
Attr RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr RefSpeed.DefTrend = "ABB:Class-ABB_ACS800_1-Template.TrendRefSpeed"
Attr PowerUpTime = 1.500000e+01
Attr AlarmLocalMod = "Frequency converter
control location is local,
"
Attr AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr AlarmWarning = "Frequency converter warning, "
Attr AlarmError = "Frequency converter error, "
Attr DefTrend = "ABB:Class-ABB_ACS800_1-Template.PlotGroup"
...
...
@@ -11929,10 +11929,10 @@ ABB ACS800 Typ 1"
EndObject
EndObject
Object Template ABB_ACS800MotorAggr 2148761600 12-OCT-2005 12:58:20.00
Body RtBody
06-DEC-2005 16:07:32.85
Attr AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:29:23.78
Attr AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr AlarmTextStartNoOk = "Power is not on, "
Attr CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Contactor.FbTimeLimit = 1.000000e+00
Attr Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -11960,9 +11960,9 @@ ABB ACS800 Typ 1"
Attr ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr ACS800.PowerUpTime = 1.500000e+01
Attr ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr ACS800.AlarmWarning = "Frequency converter warning, "
Attr ACS800.AlarmError = "Frequency converter error, "
Attr ACS800.DefTrend = "ABB:Class-ABB_ACS800MotorAggr-Template.ACS800.PlotGroup"
...
...
@@ -12003,6 +12003,9 @@ ABB ACS800 Typ 1"
Attr ACS800.PlotGroup.YUnit[2] = "A"
Attr ACS800.PlotGroup.NumPoints = 478
Attr SafetySwitch.AlarmText = "Safety switch is off, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -21871,10 +21874,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800PumpAggr 2151120896 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 16:21:15.77
Attr Super.AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr Super.AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr Super.AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:29:54.52
Attr Super.AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr Super.AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -21885,9 +21888,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.ActCurrent.PresMaxLimit = 5.000000e+01
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr Super.ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr Super.ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800PumpAggr-Template.Super.ACS800.PlotGroup"
...
...
@@ -21928,6 +21931,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -22046,10 +22052,10 @@ ABB ACS800 Aggregate
EndObject
EndObject
Object Template ABB_ACS800FanAggr 2151383040 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 16:23:59.95
Attr Super.AlarmTextToOften = "
Start up converter (power on) to often, wait before try again
"
Attr Super.AlarmTextPowOnNotOk = "
Check interlocks! Start up (power on) converter is not allowed
"
Attr Super.AlarmTextStartNoOk = "Power is not on,
start is not allowed
"
Body RtBody
23-JAN-2006 09:30:28.13
Attr Super.AlarmTextToOften = "
Power not yet ready for restart, wait before retry,
"
Attr Super.AlarmTextPowOnNotOk = "
Power interlocked,
"
Attr Super.AlarmTextStartNoOk = "Power is not on, "
Attr Super.CircuitBreaker.AlarmText = "Circuit breaker tripped, "
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
Attr Super.Contactor.AlarmText = "Feedback contactor lost, "
...
...
@@ -22077,9 +22083,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.RefSpeed.SigChanCon = "$IoConnect:ABB-Class-ABB_ACS_PPO5.O_REF"
Attr Super.ACS800.RefSpeed.PresMaxLimit = 2.000000e+03
Attr Super.ACS800.PowerUpTime = 1.500000e+01
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
control location is local,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
you must reset
, "
Attr Super.ACS800.AlarmFanOld = "
Replace cooling fan in frequency converter
, "
Attr Super.ACS800.AlarmLocalMod = "Frequency converter
is in local mode,
"
Attr Super.ACS800.AlarmTripped = "Frequency converter tripped,
reset is required
, "
Attr Super.ACS800.AlarmFanOld = "
Maintenance replace of cooling fan in converter required
, "
Attr Super.ACS800.AlarmWarning = "Frequency converter warning, "
Attr Super.ACS800.AlarmError = "Frequency converter error, "
Attr Super.ACS800.DefTrend = "ABB:Class-ABB_ACS800FanAggr-Template.Super.ACS800.PlotGroup"
...
...
@@ -22120,6 +22126,9 @@ ABB ACS800 Aggregate
Attr Super.ACS800.PlotGroup.YUnit[2] = "A"
Attr Super.ACS800.PlotGroup.NumPoints = 478
Attr Super.SafetySwitch.AlarmText = "Safety switch is off, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
...
...
@@ -22201,7 +22210,7 @@ ABB ACS800 Aggregate
! signal r i sin tur knuten till signalnamnet "ActTorque" i objektet
! "ABB_ACS800_1".
!
! OBS
!
! OBS
! vriga instllningar i omriktaren som mste till fr en fungerande
! kommunikation beaktas inte hr.
!
...
...
bcomp/wbl/bcomp/src/basecomponent.wb_load
View file @
c71c2b13
...
...
@@ -57885,11 +57885,12 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseActuatorA 2176286720 01-JAN-1970 01:00:00.00
Body RtBody
03-OCT-2005 14:10:42.58
Body RtBody
23-JAN-2006 09:31:54.36
Attr Order.Unit = "%"
Attr Order.PresMaxLimit = 1.000000e+02
Attr Position.PresMaxLimit = 1.000000e+02
Attr Mode.OpNoLocal = 1
Attr Mode.OpMaxRefMan = 1.000000e+02
Attr Mode.AlarmLocalMode = "Local mode is activated, "
Attr MaxPosDiff = 5.000000e+00
Attr DiffAlarmDelay = 1.000000e+01
...
...
@@ -66517,12 +66518,13 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseCValve 2177073152 01-JAN-1970 01:00:00.00
Body RtBody
03-OCT-2005 14:10:21.13
Body RtBody
23-JAN-2006 09:34:07.12
Attr Actuator.GraphConfiguration = 4
Attr Actuator.Order.Unit = "%"
Attr Actuator.Order.PresMaxLimit = 1.000000e+02
Attr Actuator.Position.PresMaxLimit = 1.000000e+02
Attr Actuator.Mode.OpNoLocal = 1
Attr Actuator.Mode.OpMaxRefMan = 1.000000e+02
Attr Actuator.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Actuator.MaxPosDiff = 5.000000e+00
Attr Actuator.DiffAlarmDelay = 1.000000e+01
...
...
@@ -77365,7 +77367,10 @@ Alarm HH, H, L, LL"
EndObject
EndObject
Object Template BaseMotor 2177859584 01-JAN-1970 01:00:00.00
Body RtBody 01-DEC-2005 08:56:14.11
Body RtBody 23-JAN-2006 09:32:17.05
Attr GraphConfiguration = 2
Attr DisableTempSwitch = 1
Attr TempSwitch.Super.DisableSwitch = 1
Attr TempSwitch.Super.AlarmText = "High motor temperature, "
Attr DisableTempSensor = 1
Attr TempSensor.Super.DisableValue = 1
...
...
@@ -89907,7 +89912,7 @@ Safety switch"
EndObject
EndObject
Object Template BaseMotorAggr 2182316032 01-JAN-1970 01:00:00.00
Body RtBody
01-DEC-2005 08:57:09
.70
Body RtBody
23-JAN-2006 09:32:37
.70
Attr Contactor.Order.Description = "Energize contactor"
Attr Contactor.Feedback.Description = "Contactor is energized"
Attr Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -89921,8 +89926,12 @@ Safety switch"
Attr Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
Attr Motor.TempSensor.Super.Value.Unit = "C"
Attr Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -95266,7 +95275,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseFanAggr 2183364608 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:58:47.74
Body RtBody
23-JAN-2006 09:32:57.88
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -95280,8 +95289,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -95380,7 +95393,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BasePumpAggr 2184675328 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:58:11.81
Body RtBody
23-JAN-2006 09:33:14.26
Attr Super.Contactor.Order.Description = "Energize contactor"
Attr Super.Contactor.Feedback.Description = "Contactor is energized"
Attr Super.Contactor.FbTimeLimit = 1.000000e+00
...
...
@@ -95394,8 +95407,12 @@ Motor aggregat"
Attr Super.Mode.Alarm1LocalMod = "Local mode is activated, remote control is not allowed, "
Attr Super.Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Super.Mode.AlarmNotManOrd = "Automode active. Manual start/stop order is not allowed, "
Attr Super.Motor.GraphConfiguration = 2
Attr Super.Motor.DisableTempSwitch = 1
Attr Super.Motor.TempSwitch.Super.DisableSwitch = 1
Attr Super.Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Super.Motor.DisableTempSensor = 1
Attr Super.Motor.TempSensor.Super.DisableValue = 1
Attr Super.Motor.TempSensor.Super.Value.Unit = "C"
Attr Super.Motor.TempSensor.Super.Value.PresMaxLimit = 1.500000e+02
Attr Super.Motor.TempSensor.Super.LimitHH.AlarmText = "High High motor temperature, "
...
...
@@ -96168,7 +96185,7 @@ Motor aggregat"
EndObject
EndObject
Object Template BaseMotorIncrDecrAggr 2185199616 01-JAN-1970 01:00:00.00
Body RtBody
16-DEC-2005 15:56:50.10
Body RtBody
23-JAN-2006 09:33:39.14
Attr ContactorIncr.Order.Description = "Energize contactor"
Attr ContactorIncr.Feedback.Description = "Contactor is energized"
Attr ContactorIncr.FbTimeLimit = 1.000000e+00
...
...
@@ -96188,6 +96205,9 @@ Motor aggregat"
Attr Mode.Alarm2LocalMod = "Local mode is activated, "
Attr Mode.AlarmNotManOrd = "Automode active. Manual order is not allowed, "
Attr Mode.AlarmOrderTimeOut = "Timeout, limit switch not reached, "
Attr Motor.GraphConfiguration = 2
Attr Motor.DisableTempSwitch = 1
Attr Motor.TempSwitch.Super.DisableSwitch = 1
Attr Motor.TempSwitch.Super.AlarmText = "High motor temperature, "
Attr Motor.DisableTempSensor = 1
Attr Motor.TempSensor.Super.DisableValue = 1
othermanu/wbl/mcomp/src/othermanufacturer.wb_load
View file @
c71c2b13
...
...
@@ -38,12 +38,12 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Ventim_Valve_VM3001 2147975168 06-OCT-2005 09:28:20.00
Body RtBody
01-JAN-1970 01:00:00.00
Body RtBody
23-JAN-2006 09:22:29.15
Attr Super.Super.Specification = "Ventim Butterfly valve VM3001"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/ventim_valve_vm3001.pdf"
Attr Super.SwitchOpen.Description = "Valve is open"
Attr Super.SwitchClosed.Description = "Valve is closed"
Attr Super.AlarmText = "Valve error"
Attr Super.AlarmText = "Valve error
,
"
EndBody
EndObject
EndObject
...
...
@@ -118,7 +118,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
EndObject
EndObject
Object Template Bernard_Actuator_OA 2150858752 06-OCT-2005 09:28:20.00
Body RtBody
06-OCT-2005 09:45:37.69
Body RtBody
23-JAN-2006 09:25:04.66
Attr Super.Super.Specification = "Bernard stlldon typ OA"
Attr Super.Super.DataSheet = "$pwr_lang/dsh/bernard_actuator_oa.html"
Attr Super.GraphConfiguration = 4
...
...
@@ -127,6 +127,7 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Position.Unit = "%"
Attr Super.Position.PresMaxLimit = 1.000000e+02
Attr Super.Mode.OpNoLocal = 1
Attr Super.Mode.OpMaxRefMan = 1.000000e+02
Attr Super.Mode.AlarmLocalMode = "Local mode is activated, "
Attr Super.MaxPosDiff = 5.000000e+00
Attr Super.DiffAlarmDelay = 1.000000e+01
...
...
@@ -249,9 +250,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Impac_TempSensor_IN300-Template.Super.Super.Value.ActualValue"
...
...
@@ -377,9 +378,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, levelsensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, levelsensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, levelsensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, levelsensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Mobrey_LevelSensor_MSP422-Template.Super.Super.Value.ActualValue"
...
...
@@ -467,9 +468,9 @@ Volume OtherManufacturer $ClassVolume 0.0.250.1
Attr Super.Super.LimitHH.Limit = 9.500000e+01
Attr Super.Super.LimitH.AlarmText = "High limit exceeded, pressuresensor "
Attr Super.Super.LimitH.Limit = 9.000000e+01
Attr Super.Super.LimitL.AlarmText = "Be
yond
Low limit, pressuresensor "
Attr Super.Super.LimitL.AlarmText = "Be
low
Low limit, pressuresensor "
Attr Super.Super.LimitL.Limit = 1.000000e+01
Attr Super.Super.LimitLL.AlarmText = "Be
yond
LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.AlarmText = "Be
low
LowLow limit, pressuresensor "
Attr Super.Super.LimitLL.Limit = 5.000000e+00
Attr Super.Super.Trend.Multiple = 1
Attr Super.Super.Trend.DataName = "OtherManufacturer:Class-Klay_PressureSensor_Series2000-Template.Super.Super.Value.ActualValue"
...
...
Write
Preview
Markdown
is supported
0%
Try again
or
attach a new file
Attach a file
Cancel
You are about to add
0
people
to the discussion. Proceed with caution.
Finish editing this message first!
Cancel
Please
register
or
sign in
to comment