Commit 2e4a0359 authored by Russ Cox's avatar Russ Cox

runtime: do not handle signals before configuring handler

There was a small window during program initialization
where a signal could come in before the handling mechanisms
were set up to handle it.  Delay the signal-handler installation
until we're ready for the signals.

Fixes #3314.

R=golang-dev, dsymonds, mikioh.mikioh
CC=golang-dev
https://golang.org/cl/5833049
parent 7694da1f
......@@ -734,6 +734,12 @@ runtime·mstart(void)
m->g0->sched.pc = (void*)-1; // make sure it is never used
runtime·asminit();
runtime·minit();
// Install signal handlers; after minit so that minit can
// prepare the thread to be able to handle the signals.
if(m == &runtime·m0)
runtime·initsig();
schedule(nil);
}
......
......@@ -342,8 +342,6 @@ runtime·check(void)
runtime·throw("float32nan2");
if(!(i != i1))
runtime·throw("float32nan3");
runtime·initsig();
}
void
......