Commit 0ae204a6 authored by Rafael J. Wysocki's avatar Rafael J. Wysocki

thermal: gov_bang_bang: Fold thermal_zone_trip_update() into its caller

Fold thermal_zone_trip_update() into bang_bang_control() which is the
only caller of it to reduce code size and make it easier to follow.

No functional impact.
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: default avatarLukasz Luba <lukasz.luba@arm.com>
Acked-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
parent 4526c581
......@@ -13,12 +13,42 @@
#include "thermal_core.h"
static void thermal_zone_trip_update(struct thermal_zone_device *tz,
/**
* bang_bang_control - controls devices associated with the given zone
* @tz: thermal_zone_device
* @trip: the trip point
* @crossed_up: whether or not the trip has been crossed on the way up
*
* Regulation Logic: a two point regulation, deliver cooling state depending
* on the previous state shown in this diagram:
*
* Fan: OFF ON
*
* |
* |
* trip_temp: +---->+
* | | ^
* | | |
* | | Temperature
* (trip_temp - hyst): +<----+
* |
* |
* |
*
* * If the fan is not running and temperature exceeds trip_temp, the fan
* gets turned on.
* * In case the fan is running, temperature must fall below
* (trip_temp - hyst) so that the fan gets turned off again.
*
*/
static void bang_bang_control(struct thermal_zone_device *tz,
const struct thermal_trip *trip,
bool crossed_up)
{
struct thermal_instance *instance;
lockdep_assert_held(&tz->lock);
dev_dbg(&tz->device, "Trip%d[temp=%d]:temp=%d:hyst=%d\n",
thermal_zone_trip_id(tz, trip), trip->temperature,
tz->temperature, trip->hysteresis);
......@@ -52,45 +82,6 @@ static void thermal_zone_trip_update(struct thermal_zone_device *tz,
instance->cdev->updated = false; /* cdev needs update */
mutex_unlock(&instance->cdev->lock);
}
}
/**
* bang_bang_control - controls devices associated with the given zone
* @tz: thermal_zone_device
* @trip: the trip point
* @crossed_up: whether or not the trip has been crossed on the way up
*
* Regulation Logic: a two point regulation, deliver cooling state depending
* on the previous state shown in this diagram:
*
* Fan: OFF ON
*
* |
* |
* trip_temp: +---->+
* | | ^
* | | |
* | | Temperature
* (trip_temp - hyst): +<----+
* |
* |
* |
*
* * If the fan is not running and temperature exceeds trip_temp, the fan
* gets turned on.
* * In case the fan is running, temperature must fall below
* (trip_temp - hyst) so that the fan gets turned off again.
*
*/
static void bang_bang_control(struct thermal_zone_device *tz,
const struct thermal_trip *trip,
bool crossed_up)
{
struct thermal_instance *instance;
lockdep_assert_held(&tz->lock);
thermal_zone_trip_update(tz, trip, crossed_up);
list_for_each_entry(instance, &tz->thermal_instances, tz_node)
thermal_cdev_update(instance->cdev);
......