power: supply: ab8500_charger: Fix VBAT interval check
When using USB charging, the AB8500 charger is periodically checking VBAT for a threshold at 3.8V. This crashes badly, as the class_for_each_device() was passed the wrong argument. I think this has maybe worked by chance in the past because of how the structs were arranged but it is leading to crashes now. Fix this up and also switch to using microvolts for the voltages like the rest of the code. Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>