ASoC: tlv320dac33: Use codec defaults for LOM/LOP and DAC power
Do not change the codec defaults for the following registers: 0x40, 0x41: Line output gains, do not use amplification 0x42: LOM/LOP Voltage hold, and selection 0x44: LOM inversion control It has been found, that the values configured to these registers can cause amplification, which can make the output of DAC33 distorted. The codec reset values are considered safe in all environmnts. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Showing
Please register or sign in to comment