Input: sysrq - supplement reset sequence with timeout functionality
Some devices have too few buttons, which it makes it hard to have a reset combo that won't trigger automatically. As such a timeout functionality that requires the combination to be held for a given amount of time before triggering is introduced. If a key combo is recognized and held for a 'timeout' amount of time, the system triggers a reset. If the timeout value is omitted the driver simply ignores the functionality. Signed-off-by: Mathieu Poirier <mathieu.poirier@linaro.org> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>