iio: adc: hx711: fix bug in sampling of data
Fix bug in sampling function hx711_cycle() when interrupt occures while PD_SCK is high. If PD_SCK is high for at least 60 us power down mode of the sensor is entered which in turn leads to a wrong measurement. Switch off interrupts during a PD_SCK high period and move query of DOUT to the latest point of time which is at the end of PD_SCK low period. This bug exists in the driver since it's initial addition. The more interrupts on the system the higher is the probability that it happens. Fixes: c3b2fdd0 ("iio: adc: hx711: Add IIO driver for AVIA HX711") Signed-off-by: Andreas Klinger <ak@it-klinger.de> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>