regulator: qcom_smd: Remove list_voltage callback for rpm_smps_ldo_ops_fixed
Use regulator_list_voltage_linear_range in rpm_smps_ldo_ops_fixed is wrong because it is used for fixed regulator without any linear range. The rpm_smps_ldo_ops_fixed is used for pm8941_lnldo which has fixed_uV set and n_voltages = 1. In this case, regulator_list_voltage() can return rdev->desc->fixed_uV without .list_voltage implementation. Fixes: 3bfbb4d1 ("regulator: qcom_smd: add list_voltage callback") Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@kernel.org>