rtc: max77686: Do not enforce (incorrect) interrupt trigger type
Interrupt line can be configured on different hardware in different way, even inverted. Therefore driver should not enforce specific trigger type - edge falling - but instead rely on Devicetree to configure it. The Maxim 77686 datasheet describes the interrupt line as active low with a requirement of acknowledge from the CPU therefore the edge falling is not correct. The interrupt line is shared between PMIC and RTC driver, so using level sensitive interrupt is here especially important to avoid races. With an edge configuration in case if first PMIC signals interrupt followed shortly after by the RTC, the interrupt might not be yet cleared/acked thus the second one would not be noticed. Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> Link: https://lore.kernel.org/r/20210526172036.183223-6-krzysztof.kozlowski@canonical.com