net: dsa: sja1105: Implement state machine for TAS with PTP clock source
Tested using the following bash script and the tc from iproute2-next: #!/bin/bash set -e -u -o pipefail NSEC_PER_SEC="1000000000" gatemask() { local tc_list="$1" local mask=0 for tc in ${tc_list}; do mask=$((${mask} | (1 << ${tc}))) done printf "%02x" ${mask} } if ! systemctl is-active --quiet ptp4l; then echo "Please start the ptp4l service" exit fi now=$(phc_ctl /dev/ptp1 get | gawk '/clock time is/ { print $5; }') # Phase-align the base time to the start of the next second. sec=$(echo "${now}" | gawk -F. '{ print $1; }') base_time="$(((${sec} + 1) * ${NSEC_PER_SEC}))" tc qdisc add dev swp5 parent root handle 100 taprio \ num_tc 8 \ map 0 1 2 3 5 6 7 \ queues 1@0 1@1 1@2 1@3 1@4 1@5 1@6 1@7 \ base-time ${base_time} \ sched-entry S $(gatemask 7) 100000 \ sched-entry S $(gatemask "0 1 2 3 4 5 6") 400000 \ clockid CLOCK_TAI flags 2 The "state machine" is a workqueue invoked after each manipulation command on the PTP clock (reset, adjust time, set time, adjust frequency) which checks over the state of the time-aware scheduler. So it is not monitored periodically, only in reaction to a PTP command typically triggered from a userspace daemon (linuxptp). Otherwise there is no reason for things to go wrong. Now that the timecounter/cyclecounter has been replaced with hardware operations on the PTP clock, the TAS Kconfig now depends upon PTP and the standalone clocksource operating mode has been removed. Signed-off-by: Vladimir Oltean <olteanv@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>