Commit 9452fbf5 authored by Steffen Dirkwinkel's avatar Steffen Dirkwinkel Committed by Andy Shevchenko

platform/x86: pmc_atom: Add CB4063 Beckhoff Automation board to critclk_systems DMI table

The CB4063 board uses pmc_plt_clk* clocks for ethernet controllers. This
adds it to the critclk_systems DMI table so the clocks are marked as
CLK_CRITICAL and not turned off.

Fixes: 648e9218 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: default avatarSteffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: default avatarAndy Shevchenko <andriy.shevchenko@linux.intel.com>
parent 368bae87
......@@ -400,6 +400,14 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
},
},
{
/* pmc_plt_clk* - are used for ethernet controllers */
.ident = "Beckhoff CB4063",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
},
},
{
/* pmc_plt_clk* - are used for ethernet controllers */
.ident = "Beckhoff CB6263",
......