staging: comedi: das6402: convert driver to use the comedi_8254 module
This driver uses an 8254 timer to generate the pacer clock used for analog input data conversion. Convert it to use the comedi_8254 module to provide support for the 8254 timer. Remove the unnecessary programming of timer 0. The private data 'count' value is never set by the driver and the timer is reset to MODE0 when the timers are initialized during the attach of the driver. Remove the unnecessart convert_src check in the (*do_cmdtest). The only valid convert_src is TRIG_TIMER. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>