Commit cec8ed3f authored by Thomas Richter's avatar Thomas Richter Committed by Kleber Sacilotto de Souza

s390/cpum_sf: Add data entry sizes to sampling trailer entry

BugLink: https://bugs.launchpad.net/bugs/1791953

[ Upstream commit 77715b7d ]

The CPU Measurement sampling facility creates a trailer entry for each
Sample-Data-Block of stored samples. The trailer entry contains the sizes
(in bytes) of the stored sampling types:
 - basic-sampling data entry size
 - diagnostic-sampling data entry size
Both sizes are 2 bytes long.

This patch changes the trailer entry definition to reflect this.

Fixes: fcc77f50 ("s390/cpum_sf: Atomically reset trailer entry fields of sample-data-blocks")
Signed-off-by: default avatarThomas Richter <tmricht@linux.ibm.com>
Reviewed-by: default avatarHendrik Brueckner <brueckner@linux.ibm.com>
Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: default avatarSasha Levin <alexander.levin@microsoft.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Signed-off-by: default avatarStefan Bader <stefan.bader@canonical.com>
Signed-off-by: default avatarKleber Sacilotto de Souza <kleber.souza@canonical.com>
parent 5479d9ea
......@@ -129,7 +129,9 @@ struct hws_trailer_entry {
unsigned int f:1; /* 0 - Block Full Indicator */
unsigned int a:1; /* 1 - Alert request control */
unsigned int t:1; /* 2 - Timestamp format */
unsigned long long:61; /* 3 - 63: Reserved */
unsigned int :29; /* 3 - 31: Reserved */
unsigned int bsdes:16; /* 32-47: size of basic SDE */
unsigned int dsdes:16; /* 48-63: size of diagnostic SDE */
};
unsigned long long flags; /* 0 - 63: All indicators */
};
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment