staging: comedi: s626: fix continuous acquisition
For the s626 driver, there is a bug in the handling of asynchronous commands on the AI subdevice when the stop source is `TRIG_NONE`. The command should run continuously until cancelled, but the interrupt handler stops the command running after the first scan. The command set-up function `s626_ai_cmd()` contains this code: switch (cmd->stop_src) { case TRIG_COUNT: /* data arrives as one packet */ devpriv->ai_sample_count = cmd->stop_arg; devpriv->ai_continous = 0; break; case TRIG_NONE: /* continous acquisition */ devpriv->ai_continous = 1; devpriv->ai_sample_count = 0; break; } The interrupt handler `s626_irq_handler()` contains this code: if (!(devpriv->ai_continous)) devpriv->ai_sample_count--; if (devpriv->ai_sample_count <= 0) { devpriv->ai_cmd_running = 0; /* ... */ } So `devpriv->ai_sample_count` is only decremented for the `TRIG_COUNT` case, but `devpriv->ai_cmd_running` is set to 0 (and the command stopped) regardless. Fix this in `s626_ai_cmd()` by setting `devpriv->ai_sample_count = 1` for the `TRIG_NONE` case. The interrupt handler will not decrement it so it will remain greater than 0 and the check for stopping the acquisition will fail. Cc: stable <stable@vger.kernel.org> Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>