iio: addac: ad74413r: update channel function set
According to the datasheet switching to a new channel function implies multiple steps. All functions must be selected for a minimum of 130 μs before changing to another function. The DAC_CODEx registers are not reset by changing channel functions. Prior to changing channel functions, it is recommended to set the DAC code to 0x0000 via the DAC_CODEx registers. Set the channel function to high impedance via the CH_FUNC_SETUPx registers before transitioning to the new channel function. After the new channel function is configured, it is recommended to wait 150 μs before updating the DAC code. Even though the channel switch is done at only at probe, where a device reset is performed, that does not guarantee that the steps prior changing to new channel function should be neglected. Signed-off-by: Antoniu Miclaus <antoniu.miclaus@analog.com> Link: https://lore.kernel.org/r/20230911142950.216687-1-antoniu.miclaus@analog.comSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>