Commit ee378aa4 authored by Lai Jiangshan's avatar Lai Jiangshan Committed by Tejun Heo

workqueue: fix possible idle worker depletion across CPU hotplug

To simplify both normal and CPU hotplug paths, worker management is
prevented while CPU hoplug is in progress.  This is achieved by CPU
hotplug holding the same exclusion mechanism used by workers to ensure
there's only one manager per pool.

If someone else seems to be performing the manager role, workers
proceed to execute work items.  CPU hotplug using the same mechanism
can lead to idle worker depletion because all workers could proceed to
execute work items while CPU hotplug is in progress and CPU hotplug
itself wouldn't actually perform the worker management duty - it
doesn't guarantee that there's an idle worker left when it releases
management.

This idle worker depletion, under extreme circumstances, can break
forward-progress guarantee and thus lead to deadlock.

This patch fixes the bug by using separate mechanisms for manager
exclusion among workers and hotplug exclusion.  For manager exclusion,
POOL_MANAGING_WORKERS which was restored by the previous patch is
used.  pool->manager_mutex is now only used for exclusion between the
elected manager and CPU hotplug.  The elected manager won't proceed
without holding pool->manager_mutex.

This ensures that the worker which won the manager position can't skip
managing while CPU hotplug is in progress.  It will block on
manager_mutex and perform management after CPU hotplug is complete.

Note that hotplug may happen while waiting for manager_mutex.  A
manager isn't either on idle or busy list and thus the hoplug code
can't unbind/rebind it.  Make the manager handle its own un/rebinding.

tj: Updated comment and description.
Signed-off-by: default avatarLai Jiangshan <laijs@cn.fujitsu.com>
Signed-off-by: default avatarTejun Heo <tj@kernel.org>
parent 552a37e9
...@@ -1825,10 +1825,45 @@ static bool manage_workers(struct worker *worker) ...@@ -1825,10 +1825,45 @@ static bool manage_workers(struct worker *worker)
struct worker_pool *pool = worker->pool; struct worker_pool *pool = worker->pool;
bool ret = false; bool ret = false;
if (!mutex_trylock(&pool->manager_mutex)) if (pool->flags & POOL_MANAGING_WORKERS)
return ret; return ret;
pool->flags |= POOL_MANAGING_WORKERS; pool->flags |= POOL_MANAGING_WORKERS;
/*
* To simplify both worker management and CPU hotplug, hold off
* management while hotplug is in progress. CPU hotplug path can't
* grab %POOL_MANAGING_WORKERS to achieve this because that can
* lead to idle worker depletion (all become busy thinking someone
* else is managing) which in turn can result in deadlock under
* extreme circumstances. Use @pool->manager_mutex to synchronize
* manager against CPU hotplug.
*
* manager_mutex would always be free unless CPU hotplug is in
* progress. trylock first without dropping @gcwq->lock.
*/
if (unlikely(!mutex_trylock(&pool->manager_mutex))) {
spin_unlock_irq(&pool->gcwq->lock);
mutex_lock(&pool->manager_mutex);
/*
* CPU hotplug could have happened while we were waiting
* for manager_mutex. Hotplug itself can't handle us
* because manager isn't either on idle or busy list, and
* @gcwq's state and ours could have deviated.
*
* As hotplug is now excluded via manager_mutex, we can
* simply try to bind. It will succeed or fail depending
* on @gcwq's current state. Try it and adjust
* %WORKER_UNBOUND accordingly.
*/
if (worker_maybe_bind_and_lock(worker))
worker->flags &= ~WORKER_UNBOUND;
else
worker->flags |= WORKER_UNBOUND;
ret = true;
}
pool->flags &= ~POOL_MANAGE_WORKERS; pool->flags &= ~POOL_MANAGE_WORKERS;
/* /*
......