thermal: trip: Avoid skipping trips in thermal_zone_set_trips()
Say there are 3 trip points A, B, C sorted in ascending temperature order with no hysteresis. If the zone temerature is exactly equal to B, thermal_zone_set_trips() will set the boundaries to A and C and the hardware will not catch any crossing of B (either way) until either A or C is crossed and the boundaries are changed. To avoid that, use non-strict inequalities when comparing the trip threshold to the zone temperature in thermal_zone_set_trips(). In the example above, it will cause both boundaries to be set to B, which is desirable because an interrupt will trigger when the zone temperature becomes different from B regardless of which way it goes. That will allow a new interval to be set depending on the direction of the zone temperature change. Fixes: 893bae92 ("thermal: trip: Make thermal_zone_set_trips() use trip thresholds") Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> Link: https://patch.msgid.link/12509184.O9o76ZdvQC@rjwysocki.net