MDEV-4490: Old-style master position points at the last GTID event after slave restart
Now whenever we reach the GTID point requested from the slave (when using GTID position to connect), we send a fake Gtid_list event. This event is used by the slave to know the current old-style position for MASTER_POS_WAIT(), and later the similar binlog position for MASTER_GTID_WAIT(). Without this fake event, if the slave is already fully up-to-date with the master, there may be no events sent at the given position for an indeterminate time.