Commit 71a00593 authored by Finn Thain's avatar Finn Thain Committed by Martin K. Petersen

ncr5380: Dont re-enter NCR5380_select()

Calling NCR5380_select() from the abort handler causes various problems.
Firstly, it means potentially re-entering NCR5380_select(). Secondly, it
means that the lock is released, which permits the EH handlers to be
re-entered. The combination results in crashes. Don't do it.

Fixes: 8b00c3d5 ("ncr5380: Implement new eh_abort_handler")
Reported-and-tested-by: default avatarMichael Schmitz <schmitzmic@gmail.com>
Cc: <stable@vger.kernel.org> # 4.5
Signed-off-by: default avatarFinn Thain <fthain@telegraphics.com.au>
Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
parent 1678847e
......@@ -2302,6 +2302,9 @@ static bool list_del_cmd(struct list_head *haystack,
* If cmd was not found at all then presumably it has already been completed,
* in which case return SUCCESS to try to avoid further EH measures.
* If the command has not completed yet, we must not fail to find it.
*
* The lock protects driver data structures, but EH handlers also use it
* to serialize their own execution and prevent their own re-entry.
*/
static int NCR5380_abort(struct scsi_cmnd *cmd)
......@@ -2338,15 +2341,12 @@ static int NCR5380_abort(struct scsi_cmnd *cmd)
if (list_del_cmd(&hostdata->disconnected, cmd)) {
dsprintk(NDEBUG_ABORT, instance,
"abort: removed %p from disconnected list\n", cmd);
cmd->result = DID_ERROR << 16;
if (!hostdata->connected)
NCR5380_select(instance, cmd);
if (hostdata->connected != cmd) {
complete_cmd(instance, cmd);
/* Can't call NCR5380_select() and send ABORT because that
* means releasing the lock. Need a bus reset.
*/
result = FAILED;
goto out;
}
}
if (hostdata->connected == cmd) {
dsprintk(NDEBUG_ABORT, instance, "abort: cmd %p is connected\n", cmd);
......
......@@ -2497,6 +2497,9 @@ static bool list_del_cmd(struct list_head *haystack,
* If cmd was not found at all then presumably it has already been completed,
* in which case return SUCCESS to try to avoid further EH measures.
* If the command has not completed yet, we must not fail to find it.
*
* The lock protects driver data structures, but EH handlers also use it
* to serialize their own execution and prevent their own re-entry.
*/
static int NCR5380_abort(struct scsi_cmnd *cmd)
......@@ -2533,15 +2536,12 @@ static int NCR5380_abort(struct scsi_cmnd *cmd)
if (list_del_cmd(&hostdata->disconnected, cmd)) {
dsprintk(NDEBUG_ABORT, instance,
"abort: removed %p from disconnected list\n", cmd);
cmd->result = DID_ERROR << 16;
if (!hostdata->connected)
NCR5380_select(instance, cmd);
if (hostdata->connected != cmd) {
complete_cmd(instance, cmd);
/* Can't call NCR5380_select() and send ABORT because that
* means releasing the lock. Need a bus reset.
*/
result = FAILED;
goto out;
}
}
if (hostdata->connected == cmd) {
dsprintk(NDEBUG_ABORT, instance, "abort: cmd %p is connected\n", cmd);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment