Commit 79252310 authored by Major Lee's avatar Major Lee Committed by Anton Vorontsov

intel_mid_battery: Handle Over Current gracefully

When DCDC input line over current detecting, PMIC will change charging
current automatically. Logging event is enough.
Signed-off-by: default avatarMajor Lee <major_lee@wistron.com>
Signed-off-by: default avatarAlan Cox <alan@linux.intel.com>
Signed-off-by: default avatarAnton Vorontsov <cbouatmailru@gmail.com>
parent 019370d3
......@@ -61,7 +61,8 @@ MODULE_PARM_DESC(debug, "Flag to enable PMIC Battery debug messages.");
#define PMIC_BATT_CHR_SBATDET_MASK (1 << 5)
#define PMIC_BATT_CHR_SDCLMT_MASK (1 << 6)
#define PMIC_BATT_CHR_SUSBOVP_MASK (1 << 7)
#define PMIC_BATT_CHR_EXCPT_MASK 0xC6
#define PMIC_BATT_CHR_EXCPT_MASK 0x86
#define PMIC_BATT_ADC_ACCCHRG_MASK (1 << 31)
#define PMIC_BATT_ADC_ACCCHRGVAL_MASK 0x7FFFFFFF
......@@ -304,11 +305,6 @@ static void pmic_battery_read_status(struct pmic_power_module_info *pbi)
pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
pmic_battery_log_event(BATT_EVENT_BATOVP_EXCPT);
batt_exception = 1;
} else if (r8 & PMIC_BATT_CHR_SDCLMT_MASK) {
pbi->batt_health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
pmic_battery_log_event(BATT_EVENT_DCLMT_EXCPT);
batt_exception = 1;
} else if (r8 & PMIC_BATT_CHR_STEMP_MASK) {
pbi->batt_health = POWER_SUPPLY_HEALTH_OVERHEAT;
pbi->batt_status = POWER_SUPPLY_STATUS_NOT_CHARGING;
......@@ -316,6 +312,10 @@ static void pmic_battery_read_status(struct pmic_power_module_info *pbi)
batt_exception = 1;
} else {
pbi->batt_health = POWER_SUPPLY_HEALTH_GOOD;
if (r8 & PMIC_BATT_CHR_SDCLMT_MASK) {
/* PMIC will change charging current automatically */
pmic_battery_log_event(BATT_EVENT_DCLMT_EXCPT);
}
}
}
......
Markdown is supported