Input: sun4i-ts - A10 (sun4i) has a different temperature curve
Testing has revealed that the temperature in the rtp controller of the A10 (sun4i) SoC has a different curve then on the A13 (sun5i) and later models. Add a new sun5i-a13-ts compatible to differentiate the newer models and set the curve based on the compatible string. The new curve is still not ideal on all A10-s, that seems to have to do with there being a large spread between different A10-s out there, the new curve us based on callibration results on 4 completely different models: raw min raw max temp min temp max stepsize offset Tong Zhang's hackberry 2402 2680 45.0 80.0 0.125 -255.3 Hansg's Cubieboard 2207 2300 36.0 45.0 0.096 -175.8 Olliver's lime 1 (*): 2258 2537 48.3 87.1 0.139 -265.7 Olliver's lime 2 (*): 2222 2486 46.7 91.7 0.170 -331.0 *) from: http://linux-sunxi.org/Temperature_Calibration Average all 4: 0.133 -257.0 Average without outliers (middle 2): 0.132 -261.0 Since it is better to slightly overreport the temperature this patch uses the average of all 4 as curve. This fixes the temperature reported on the A10 being much higher then expected. Reported-by: Tong Zhang <lovewilliam@gmail.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>