playbook: fix init-sdr for recent version of amarisoft
TODO: fix the check, it should check the PCB number and not the Amarisoft version.
Showing
-
Maintainer
Checking the PCB number seems a bit complicated since I guess we would need to check which are v3 and which have broken VCXO, so for now I will not implement it yet. However I changed it so that it checks if version is not 2021 (2022 versions do not work anyway because of tdd_tx_mod issue so I ignore these), that way the script will continue working for versions >= 2025 : c6cd6bd5