Commit 604eb7fc authored by Vincent Pelletier's avatar Vincent Pelletier

Make OperationalError 1054 a valid condition to recreate cache table.

git-svn-id: https://svn.erp5.org/repos/public/erp5/trunk@25092 20353a03-c40f-0410-a6d1-a30d3c3de9de
parent 9c5edad5
No related merge requests found
......@@ -34,7 +34,7 @@ from Acquisition import aq_base
from Persistence import Persistent
from Globals import PersistentMapping
from itertools import izip
from MySQLdb import ProgrammingError
from MySQLdb import ProgrammingError, OperationalError
def DCWorkflowDefinition_notifyWorkflowMethod(self, ob, transition_list, args=None, kw=None):
'''
......@@ -637,7 +637,10 @@ def WorkflowTool_refreshWorklistCache(self):
if len(value_column_dict[COUNT_COLUMN_TITLE]):
try:
Base_zInsertIntoWorklistTable(**value_column_dict)
except ProgrammingError:
except (ProgrammingError, OperationalError), error_value:
# OperationalError 1054 = unknown column
if isinstance(error_value, OperationalError) and error_value[0] != 1054:
raise
LOG('WorkflowTool', 100, 'Insertion in worklist cache table ' \
'failed. Recreating table and retrying.',
error=sys.exc_info())
......