- 26 Sep, 2002 3 commits
-
-
Guido van Rossum authored
simple read-only tests. (These tests pass.)
-
Guido van Rossum authored
StorageServer as well as that of the storage itself. Currently the test fails.
-
Guido van Rossum authored
start_zeo_server() has changed dramatically.)
-
- 25 Sep, 2002 6 commits
-
-
Jeremy Hylton authored
-
Jeremy Hylton authored
Don't catch a specific set of errors, catch anything, log the message that failed, and re-raise the exception. Eliminate unused class variable VERSION and unused import of struct.
-
Jeremy Hylton authored
If an exception occurs while decoding a message, there is really nothing the server can do to recover. If the message was a synchronous call, the client will wait for ever for the reply. The server can't send the reply, because it couldn't unpickle the message id. Instead of trying to recover, just let the exception propogate up to asyncore where the connection will be closed. As a result, eliminate DecodingError and special case in handle_error() that handled flags == None.
-
Guido van Rossum authored
instead. return_error(): be more careful calling repr() on err_value.
-
Barry Warsaw authored
which tests a particular combination of packing and transactional undo at the ZODB layer.
-
Barry Warsaw authored
FileStorage/Berkeley storage definition, and undoInfo(), and the storage interface definition.
-
- 24 Sep, 2002 2 commits
-
-
Jeremy Hylton authored
This is no longer an invariant. Storage methods like restore(), abortVersion(), and commitVersion() can result in a serialno that does not match the transaction id.
-
Guido van Rossum authored
Rather than blaming window for reporting success as an error, the else clause on the second try block should be an except clause.
-
- 23 Sep, 2002 5 commits
-
-
Guido van Rossum authored
ZODB/Connection.py -- the Connection class has a sync() method which calls the sync() method on the storage if it exists.
-
Guido van Rossum authored
- Change pending() to use select.select() instead of select.poll(), so it'll work on Windows. - Clarify comment to say that only Exceptions are propagated. - Change some private variables to public (everything else is public). - Remove XXX comment about logging at INFO level (we already do that now :-).
-
Guido van Rossum authored
-
Guido van Rossum authored
XXX This created two unused attributes, self._commit_lock_{acquire,release}. Why? I've gotten rid of them. The test suite succeeds. But they are created by BaseStorage; maybe they play a role in the standard storage API???
-
Guido van Rossum authored
-
- 20 Sep, 2002 3 commits
-
-
Guido van Rossum authored
-
Guido van Rossum authored
ClientStorage constructor called with both wait=1 and read_only_fallback=1 should return, indicating its readiness, when a read-only connection was made. This is done by calling connect(sync=1). Previously this waited for the ConnectThread to finish, but that thread doesn't finish until it's made a read-write connection, so a different mechanism is needed. I ended up doing a major overhaul of the interfaces between ClientStorage, ConnectionManager, ConnectThread/ConnectWrapper, and even ManagedConnection. Changes: ClientStorage.py: ClientStorage: - testConnection() now returns just the preferred flag; stubs are cheap and I like to have the notifyConnected() signature be the same for clients and servers. - notifyConnected() now takes a connection (to match the signature of this method in StorageServer), and creates a new stub. It also takes care of the reconnect business if the client was already connected, rather than the ClientManager. It stores the connection as self._connection so it can close the previous one. This is also reset by notifyDisconnected(). zrpc/client.py: ConnectionManager: - Changed self.thread_lock into a condition variable. It now also protects self.connection. The condition is notified when self.connection is set to a non-None value in connect_done(); connect(sync=1) waits for it. The self.connected variable is no more; we test "self.connection is not None" instead. - Tried to made close() reentrant. (There's a trick: you can't set self.connection to None, conn.close() ends up calling close_conn() which does this.) - Renamed notify_closed() to close_conn(), for symmetry with the StorageServer API. - Added an is_connected() method so ConnectThread.try_connect() doesn't have to dig inside the manager's guts to find out if the manager is connected (important for the disposition of fallback wrappers). ConnectThread and ConnectWrapper: - Follow above changes in the ClientStorage and ConnectionManager APIs: don't close the manager's connection when reconnecting, but leave that up to notifyConnected(); ConnectWrapper no longer manages the stub. - ConnectWrapper sets self.sock to None once it's created a ManagedConnection -- from there on the connection is is charge of closing the socket. zrpc/connection.py: ManagedServerConnection: - Changed the order in which close() calls things; super_close() should be last. ManagedConnection: - Ditto, and call the manager's close_conn() instead of notify_closed(). tests/testZEO.py: - In checkReconnectSwitch(), we can now open the client storage with wait=1 and read_only_fallback=1.
-
Guido van Rossum authored
constructor signature backwards compatible with ZEO 1. This means adding wait_for_server_on_startup and debug options. wait_for_server_on_startup is an alias for wait, which makes the argument decoding for these two a little tricky. debug is ignored. Also change the default of wait to True, like it was in ZEO 1. This is less likely to screw naive customers.
-
- 19 Sep, 2002 8 commits
-
-
Guido van Rossum authored
-
Guido van Rossum authored
of 30 seconds. There's nothing wrong with the code, it's just slow. So increase the timeout to 60 seconds.
-
Guido van Rossum authored
On Windows, port+1 is used as well, so we don't want accidentally to allocate two adjacent ports when we ask for multiple ports.
-
Guido van Rossum authored
-
Guido van Rossum authored
"if wait" rather than "if wait is not None". Also change the default to 0.
-
Guido van Rossum authored
until I added an is_connected() test to testConnection() is solved. After the ConnectThread has switched the client to the new, read-write connection, it closes the read-only connection(s) that it was saving up in case there was no read-write connection. But closing a ManagedConnection calls notify_closed() on the manager, which disconnected the manager and the client from its brand new read-write connection. The mistake here is that this should only be done when closing the manager's current connection! The fix was to add an argument to notify_closed() that passes the connection object being closed; notify_closed() returns without doing a thing when that is not the current connection. I presume this didn't happen on Linux because there the sockets happened to connect in a different order, and there was no read-only connection to close yet (just a socket trying to connect). I'm taking out the previous "fix" to ClientStorage, because that only masked the problem in this relatively simple test case. The problem could still occur when both a read-only and a read-write server are up initially, and the read-only server connects first; once the read-write server connects, the read-write connection is installed, and then the saved read-only connection is closed which would again mistakenly disconnect the read-write connection. Another (related) fix is not to call self.mgr.notify_closed() but to call self.mgr.connection.close() when reconnecting. (Hmm, I wonder if it would make more sense to have an explicit reconnect callback to the manager and the client? Later.)
-
Guido van Rossum authored
the socket's __str__ due to a __getattr__ method in asyncore's dispatcher base class that everybody hates but nobody dares take away.
-
Guido van Rossum authored
Add the pid to the label.
-
- 18 Sep, 2002 2 commits
-
-
Guido van Rossum authored
When load() finds a hit in the non-current file, copy it to the current file (except when this would cause a cache flip). It is hoped that this improves the cache performance. (Now merged into the trunk! Jeremy & Jim want this in the ZEO and ZODB3 beta2 releases.)
-
Guido van Rossum authored
The fix is to change testConnection() to only retry the register() call with the read-only flag set when we're not alrady connected. But I don't understand why this fix is needed; I'll keep debugging.
-
- 17 Sep, 2002 11 commits
-
-
Guido van Rossum authored
-
Guido van Rossum authored
calls. If multiple threads sharing a ZEO connection want to make overlapping calls, they can do that now. This is mostly useful when one thread is waiting for a long-running pack() or undo*() call -- the other thread can now proceed. Jeremy & I did a review of the StorageServer code and found no place where overlapping incoming calls from the same connection could do any harm -- given that the only places where incoming calls can be handled are those places where the server makes a callback to the client.
-
Guido van Rossum authored
Cleanup comments for Managed*Connection. Whitespace normalization.
-
Guido van Rossum authored
- It never uses self.conn. So don't store it. - Make a check in register() that register() isn't called twice. If it is, log a message and raise ValueError.
-
Guido van Rossum authored
-
Guido van Rossum authored
trying to fake a tpc_abort() call with the right transaction id, call a new method abort(), which resets some instance variables and then calls the strategy's abort() method. The immediate strategy's abort() aborts its own transaction and then calls the zeo_storage's handle_waiting() method to restart the next blocked transaction from the _waiting list; the delayed strategy's abort() removes the zeo_storage from the _waiting list.
-
Casey Duncan authored
-
Guido van Rossum authored
- Remove unused imports. - Got rid of \ continuation lines. - Remove leading underscores from all names of methods and instance variables of ZEOStorage. There was no usage consistency and I don't see any other reason to maintain the existing names.
-
Guido van Rossum authored
a variety of exceptions. Catch all of them. (The only ones I've seen are Disconnected and ReadOnlyError, but since we're disconnected abruptly as part of the switch, it's possible to see any of the exceptions that checkReconnection() catches.)
-
Guido van Rossum authored
read-write server now works!!!
-
Guido van Rossum authored
unlocking bug in new_oid().
-