runtime: do not use PowerRegisterSuspendResumeNotification on systems with "program time" timer
Systems where PowerRegisterSuspendResumeNotification returns ERROR_ FILE_NOT_FOUND are also systems where nanotime() is on "program time" rather than "real time". The chain for this is: powrprof.dll!PowerRegisterSuspendResumeNotification -> umpdc.dll!PdcPortOpen -> ntdll.dll!ZwAlpcConnectPort("\\PdcPort") -> syscall -> ntoskrnl.exe!AlpcpConnectPort Opening \\.\PdcPort fails with STATUS_OBJECT_NAME_NOT_FOUND when pdc.sys hasn't been initialized. Pdc.sys also provides the various hooks for sleep resumption events, which means if it's not loaded, then our "real time" timer is actually on "program time". Finally STATUS_OBJECT_NAME_ NOT_FOUND is passed through RtlNtStatusToDosError, which returns ERROR_ FILE_NOT_FOUND. Therefore, in the case where the function returns ERROR_ FILE_NOT_FOUND, we don't mind, since the timer we're using will correspond fine with the lack of sleep resumption notifications. This applies, for example, to Docker users. Fixes #35447 Fixes #35482 Change-Id: I9e1ce5bbc54b9da55ff7a3918b5da28112647eee Reviewed-on: https://go-review.googlesource.com/c/go/+/208317Reviewed-by: Jason A. Donenfeld <Jason@zx2c4.com> Reviewed-by: Austin Clements <austin@google.com> Run-TryBot: Jason A. Donenfeld <Jason@zx2c4.com> TryBot-Result: Gobot Gobot <gobot@golang.org>