Commit 5f69e739 authored by Shenghou Ma's avatar Shenghou Ma Committed by Minux Ma

runtime: adjust traceTickDiv for non-x86 architectures

Fixes #10554.
Fixes #10623.

Change-Id: I90fbaa34e3d55c8758178f8d2e7fa41ff1194a1b
Signed-off-by: default avatarShenghou Ma <minux@golang.org>
Reviewed-on: https://go-review.googlesource.com/9247Reviewed-by: default avatarDmitry Vyukov <dvyukov@google.com>
Reviewed-by: default avatarDave Cheney <dave@cheney.net>
parent ffd33449
......@@ -60,8 +60,13 @@ const (
// Timestamps in trace are cputicks/traceTickDiv.
// This makes absolute values of timestamp diffs smaller,
// and so they are encoded in less number of bytes.
// 64 is somewhat arbitrary (one tick is ~20ns on a 3GHz machine).
traceTickDiv = 64
// 64 on x86 is somewhat arbitrary (one tick is ~20ns on a 3GHz machine).
// The suggested increment frequency for PowerPC's time base register is
// 512 MHz according to Power ISA v2.07 section 6.2, so we use 16 on ppc64
// and ppc64le.
// Tracing won't work reliably for architectures where cputicks is emulated
// by nanotime, so the value doesn't matter for those architectures.
traceTickDiv = 16 + 48*(goarch_386|goarch_amd64|goarch_amd64p32)
// Maximum number of PCs in a single stack trace.
// Since events contain only stack id rather than whole stack trace,
// we can allow quite large values here.
......
Markdown is supported