Other Plantronics headset models seem requiring the same workaround as C320-M to add the 20ms delay for the control messages, too. Apply the workaround generically for devices with the vendor ID 0x047f. Note that the problem didn't surface before 5.11 just with luck. Since 5.11 got a big code rewrite about the stream handling, the parameter setup procedure has changed, and this seemed triggering the problem more often. BugLink: https://bugzilla.suse.com/show_bug.cgi?id=1182552 Cc: <stable@vger.kernel.org> Link: https://lore.kernel.org/r/20210304085009.4770-1-tiwai@suse.deSigned-off-by: Takashi Iwai <tiwai@suse.de>