Hans de Goede authored
The sch5627 needs to be explicitly told to start an adc conversion for Vbat, once in a while. Without this Vbat may read 0, and will never get updated. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Jean Delvare <khali@linux-fr.org>