Zheng Wang authored
In bq24190_probe, &bdi->input_current_limit_work is bound with bq24190_input_current_limit_work. When external power changed, it will call bq24190_charger_external_power_changed to start the work. If we remove the module which will call bq24190_remove to make cleanup, there may be a unfinished work. The possible sequence is as follows: CPU0 CPUc1 |bq24190_input_current_limit_work bq24190_remove | power_supply_unregister | device_unregister | power_supply_dev_release| kfree(psy) | | | power_supply_get_property_from_supplier | //use Fix it by finishing the work before cleanup in the bq24190_remove Fixes: 97774672 ("power_supply: Initialize changed_work before calling device_add") Signed-off-by: Zheng Wang <zyytlz.wz@163.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
47c29d69