    ARM: tegra: define Jetson TK1 regulators · 22b35776
    Stephen Warren authored
    These are mostly identical to the Venice2 regulator definitions, since
    the board designs are very similar. Differences are:
    
    - Jetson TK1 doesn't have a built-in LCD panel, so on-board regulators
      are not present for the backlight, touchscreen, or panel.
    - +3.3V_RUN needs to be boot-on/always-on, since it's widely used. This
      change should likely be propagated to Venice2 for completeness,
      although it will have no practical effect there since various other
      regulators use +3.3V_RUN as their supply and are always-on.
    - +3.3V_LP0 needs to be boot-on as well as always-on. One reason
      is because it's used to driver the UART level-shifter; without this, I
      see a brief period of UART corruption during cold boots.I suspect this
      change needs to be propagated to Venice2, and we simply haven't noticed
      the need since there's no UART level-shifter on Venice2.
    - A few rails have different names in the schematics.
    Signed-off-by: default avatarStephen Warren <swarren@nvidia.com>
    22b35776