Stephen Warren authored
These are mostly identical to the Venice2 regulator definitions, since the board designs are very similar. Differences are: - Jetson TK1 doesn't have a built-in LCD panel, so on-board regulators are not present for the backlight, touchscreen, or panel. - +3.3V_RUN needs to be boot-on/always-on, since it's widely used. This change should likely be propagated to Venice2 for completeness, although it will have no practical effect there since various other regulators use +3.3V_RUN as their supply and are always-on. - +3.3V_LP0 needs to be boot-on as well as always-on. One reason is because it's used to driver the UART level-shifter; without this, I see a brief period of UART corruption during cold boots.I suspect this change needs to be propagated to Venice2, and we simply haven't noticed the need since there's no UART level-shifter on Venice2. - A few rails have different names in the schematics. Signed-off-by:
Stephen Warren <swarren@nvidia.com>
22b35776